Impact of Fluoride on the Corrosion Pattern of Pure Titanium and Titanium Alloy Combined with Nickel-Chromium Alloy and Gold Alloy: An In-vitro Study

Author:

Raja S Ramesh,Rajambigai M Aarti,Giri TC,Amalorpavam V,Kumar Tamilselvan

Abstract

Introduction: Currently, Fluoride ions are added to commercially available tooth paste, mouth washes and cariostatic gels for their prophylactic action. However, the preventive effect may also be accompanied by the corrosive activity, through infiltration of fluoride-containing saliva in the contact between crowns and bridges or into the implant supported structure. Aim: To evaluate the corrosion action of Sodium Fluoride (NaF) on Pure Titanium (PT) and its alloy coupled with NickelChromium (Ni-Cr) alloy (NC) and Gold (Au) Alloy (GA). Materials and Methods: This in-vitro study was conducted in the Department of Prosthodontics at Central Electrochemical Research Institute, Karaikudi, Tamil Nadu, India. The duration of the study was six months, from April 2010 to September 2010. A total of 48 specimens were categorised under four groups. The four groups included for the study were pure group I (PT+GA), group II (PT+NC alloy), group III {Titanium Alloy (TA)+GA) and group IV (TA+NC alloy}. The specimens under each group were divided into half and were immersed in 100 mL of either artificial saliva or artificial saliva with 1000 Parts Per Million (ppm) fluoride. The current was passed at a scanning rate of 1800 mV/hour for 60 minutes and changes in corrosion potential were observed. The elemental release analysis test was conducted by using inductively coupled plasma-mass spectrometry to quantitatively analyse the elements (metal ions) released in the test solution from the galvanic coupling alloys. In order to evaluate the corrosion behaviour, the surfaces of the specimens were examined with an optical microscope (Eclipse LV100D, Nikon, USA). Analysis of Variance (ANOVA) was done for intergroup comparison. Statistical significance was set at 5%. Results: The mean value of corrosion of PT+GA and PT+NC was 13 μg/cm2 and 27 μg/cm2 respectively. The mean value of corrosion of TA+GA and TA+NC was 12 μg/cm2 and 24 μg/cm2 respectively, in artificial saliva without sodium fluoride. In the presence of sodium fluoride, the mean value of corrosion of PT+GA and PT+NC was 17 μg/cm2 and 60 μg/cm2 respectively, and the mean value of corrosion of TA+GA and TA+NC was 15 μg/cm2 and 41 μg/cm2 . The PT and TA specimens coupled with NC alloy specimens showed more corrosion in saliva either with or without sodium fluoride compared to GA. Conclusion: The NC alloy specimens coupled with PT and TA specimens showed severe pitting corrosion in artificial saliva containing sodium fluoride.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3