A Dosimetric Study of Volumetric Arc Modulation with RapidArc Versus Intensity-modulated Radiotherapy inCervical Cancer Patients

Author:

Goswami Brijesh,Jain Rakesh Kumar,Yadav Suresh,Kumar Sunil,Oommen Saji,Manocha Sapna,Jadhav Ganesh K

Abstract

Introduction: The method of radiotherapy has moved away from two-dimensional and three-dimensional conformal radiotherapy towards Volumetric-Modulated Arc Therapy (VMAT) for advanced carcinomas. VMAT treatments often result in significant clinical advantage, particularly when concave dose distributions are required as is often the situation since these tumours are in close proximity to several critical structures. Aim:To investigate the potential clinical role of volumetric arc therapy on cervical cancer patients and its comparison with fixed-field Intensity-Modulated Radiotherapy (IMRT) was used as a benchmark. Materials and Methods: Retrospectively, radiotherapy treatment plans of fifteen cervical cancer patients were selected for this study. These patients were previously treated with sliding window IMRT techniques during January 2020 to November 2020. For dosimetric comparison of sliding window IMRT techniques with RapidArc, a new set of plans were created using VMAT/RapidArc technique. For each patient two plans were generated and in this way total 30 plans were analysed. The prescription dose to Planning Target Volume (PTV) was 50.4 Gy in 28 fractions (1.8Gy/fraction) for the 6 MV photon beam. Comparison of each plan done on the basis of Organs At Risk (OARs) sparing, coverage index (C), Conformity Index (CI), Homogeneity Index (HI), dose Gradient Index (GI), and Unified Dosimetry Index (UDI). This study utilised UDI scoring for evaluation and comparison of RapidArc and IMRT plans. Treatment Time (TT) for patient comfort and the number of Monitor Units (MUs) for long-term side-effects was also taken into consideration. A paired two-tailed t-test was executed for the dosimetric study of volumetric arc modulation with RapidArc and its comparison with the IMRT technique in the radiotherapy treatment of cervical cancer patients. All the collected data was analysed using Statistical Package for Social Sciences (SPSS) version 20.0. The (p-value<0.05) was contemplated for the level of statistical significance. Results: Comparable target coverage and better sparing of OARs were achieved with the RapidArc technique in comparison to IMRT. As was evident with results of present study, the values of CI (1.55±0.07), HI (1.07±0.07), GI (0.98±0.01) and UDI (1.25±0.11) of RapidArc technique showed significant difference from respective values of IMRT Technique (1.67±0.06, 1.10±0.06, 0.96±0.01 and 1.38±0.13). Values of MUs (1560.47±52.16) and treatment time (3.71±0.73 mins) were significantlly high in IMRT technique as compared to RapidArc technique (542.33±51.09 and 2.39±0.35 mins respectively). Conclusion: From this study, it is clear that a similar planning goal can be achieved by RapidArc in comparison to fixed-field IMRT with less normal organ toxicity. RapidArc is a faster and precise treatment technique. The most significant change comes to see in the number of MUs and TT, which is much lesser in RapidArc.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3