Comparing the Effectiveness of Ambu® AuraGain™ Laryngeal Mask Airway with LMA® ProSeal™ in Patients Undergoing Laparoscopic Surgeries- A Randomised Clinical Trial

Author:

Manisha MK,Bharadwaj Archana Anilkumar,Kamath Shyamsunder

Abstract

Introduction: Second generation Supraglottic Airway Devices (SADs) contain a gastric drain tube which separates the respiratory and the alimentary tract. This provides a better oropharyngeal seal and reduces the risk of pulmonary aspiration of refluxed gastric contents compared to the first generation SADs. Aim: To compare Ambu® AuraGain™ (AAU) laryngeal mask airway with LMA® ProSeal ™ (PLMA) in terms of Oropharyngeal Leak Pressure (OLP) in laparoscopic surgeries. Materials and methods: This randomised clinical study was conducted from December 2017 to September 2019, at Shri Dharmasthala Manjunatheshwara College of Medical Sciences and Hospital, Dharwad, India in 80 patients, aged 18 to 65 years, of American Society of Anesthesiologists (ASA) physical status I and II undergoing laparoscopic surgeries. Patients were randomly assigned to one of the two groups: group PLMA and group AAU. After induction of anaesthesia, SADs were inserted by an experienced anaesthesiologist. OLP, pharyngeal mucosal pressure, peak airway pressure and secondary outcome parameters (the number of attempts, time required, ease, and hemodynamic response associated with insertion of LMA) were recorded at set time points. Data was analysed using Statistical Packages for Social Sciences (SPSS) version 22. Results: All patients in both the groups were comparable in terms of demographic data and baseline vital parameters. The Oropharyngeal Leak Pressure of group AAU was comparable to group PLMA at all measured time-points. The two groups were comparable in terms of pharyngeal mucosal pressure immediately after insertion of LMA, but group AAU had lesser pharyngeal mucosal pressure compared to group PLMA immediately after pneumoperitoneum, at 30 and 60 minutes. Mean peak airway pressures were lower in group AAU than group PLMA immediately after insertion of LMA (15.53±1.50 versus 17.06±2.56 cmH2 O, p=0.004) and immediately after creation of pneumoperitoneum (23.03±2.96 versus 23.03±2.96 cmH2 O, p= 0.04). Both the groups were comparable in terms of number of attempts, time taken, haemodynamic response associated with LMA insertion and with passage of gastric tube except that PLMA was easier to insert in the first attempt compared to AAU (26/40 versus 13/40, Grade 1 ease of insertion). Conclusion: Ambu® AuraGain™ could be a useful alternative to LMA® ProSeal ™ in patients undergoing laparoscopic surgeries.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3