Introduction: I-gel and classic Laryngeal Mask Airway (cLMA) are two Supraglottic Airway Devices (SAD) used for management of airway in various situations, including for management of difficult airway. Despite widespread use of these devices, there are very few trials studying I-gel and classic LMA for management of patients with difficult airway. The outcome of present study determines which SAD is better for managing difficult airway. Aim: To compare I-gel and cLMA in managing anticipated difficult airway. Materials and Methods: This randomised and single blinded clinical trial study was conducted in King George’s Medical University, Lucknow, Uttar Pradesh, India, between February 2019 to January 2020. Adult patients with Mallampati class 3 or 4, thyromental distance <6 cm, sternomental distance <12 cm, restricted neck movement, micrognathia/retrognathia or short/thick neck undergoing elective short duration surgery under general anaesthesia were included in this study. Total 50 patients divided into group C received cLMA while group I patients received I-gel for airway management. Fifty patients were recruited in each group. Nominal variables were analysed using chi-squared test. A two-sided p<0.05 were considered significant for all the tests. Analysis was performed using Statistical Package for Social Sciences (SPSS) version 25.0 for windows. Results: Mean age in group C was 40.38±12.96 (years) and in group I was 37.94±11.77 (years) with p-value 0.327. Overall (n=44 in group C, 50 in group I, p-value=0.012) and first attempt (n=10 in group C, 40 in group I, p-value <0.001) success rate of device placement was higher for I-gel. Number of attempts, manipulations, time needed to insert and Leak Fraction was significantly lower for I-gel (p-value <0.001). Compared to cLMA, Oropharyngeal Leak Pressure (OLP) was higher with I-gel. Fibreoptic view on a four-point scale was better with I-gel. Desaturation, tachycardia, bradycardia, and postoperative sore throat was more frequent with cLMA. Conclusion: Compared to cLMA, I-gel has higher success rate of insertion in patients with difficult airway and has added advantage of more rapid insertion, higher OLP and need for fewer insertion attempts and manipulations with lower rates of complications.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3