Evaluation of the Magnet Breakaway Force Measurement Accuracy of the NT-800 Sensors for Early Detection of Defects of Their Manufacturing

Author:

Kutsepau A. Yu.1,Kren A. P.1,Hnutsenka Y. V.1

Affiliation:

1. Institute of Applied Physics of the National Academy of Science of Belarus

Abstract

Сontrol of mechanical stresses formed with the deposition of nickel coatings plays an important role in the diagnosis of coatings’ technical condition. Large internal stresses can lead to cracking or flaking of coatings which is completely unacceptable for critical parts and assembly units used, for example, in space technology for which reliability is of paramount importance. An important aspect of internal stresses monitoring is the measurement error of the instruments used. The purpose of this work was to determine the characteristics of the device sensors, which make the assessment of their manufacturing possible at the preliminary stage of the measuring equipment assembling in order to maintain the required accuracy of subsequent measurements.In most cases the measurement error assessment is possible only after the equipment manufacture and calibration. In this paper it is proposed to evaluate the accuracy characteristics of device sensors based on the precision (repeatability and reproducibility) of the primary informative parameter recording. In the case of the NT-800 device that was developed at the Institute of Applied Physics of the National Academy of Sciences of Belarus the effect of precision characteristics deterioration on the eventual measurement error is demonstrated. Determining the precision parameters before establishing correlation dependences between the primary informative parameter and the measured characteristic is proposed in order to reject poorly manufactured sensors and reduce labor costs.In particular, measurements of the magnitude proportional to the magnetic breakaway force were carried out using the NT-800 device with nickel specimens simulating coatings with a thickness of 200 to 700 μm and a rolling value from 0 to 40 %. It was established that in the case of well-made sensors the variation coefficient calculated from the dispersion of repeatability is in the range 0.2–0.6 %, and the variation coefficient calculated from the dispersion of reproducibility does not exceed 0.9 %. In the case of a sensor with the sensitive element parameters worsened, the variation coefficient of repeatability and reproducibility were up by one and a half times. Deterioration of the precision characteristics resulted in significant changes in the readings of the calibrated instrument. Thus the absolute measurement error for a sensor with a poorly made sensitive element turned out to be approximately 3 times higher in the range of 200– 300 MPa than that for a sensor with good precision parameters.

Publisher

Belarusian National Technical University

Subject

General Earth and Planetary Sciences,Water Science and Technology,Geography, Planning and Development

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3