Evaluation of a self-monitoring protocol for assessing soot and polycyclic aromatic hydrocarbon exposure among chimney sweeps

Author:

Klang Therese,Molnár Peter,Lindh Christian,Storsjö Tobias,Tinnerberg Håkan

Abstract

Traditional methods for measuring chemical exposure have challenges in terms of obtaining sufficient data; therefore, improved methods for better assessing occupational exposure are needed. One possible approach to mitigate these challenges is to use self-monitoring methods such as sensors, diaries, or biomarkers. In the present study, a self-monitored method for measuring soot exposure, which included real-time air monitoring, a work diary, and the collection of urine samples, was evaluated. To validate the method, exposure measurements during the workday and diary entries were compared with velocities calculated from GPS tracking and the expected polycyclic aromatic hydrocarbon (PAH) metabolite patterns in urine. The method was applied with chimney sweeps, an occupational group at a high risk of many severe health outcomes and for whom effective control measures for reducing exposure are needed. In the study, 20 chimney sweeps followed a self-monitoring protocol for 8 consecutive workdays. Personal exposure to soot was measured as black carbon (BC) using micro-aethalometers. A diary was used to record the work tasks performed, and urine samples were collected and analysed for PAH metabolites. From the expected 160 full day measurements, 146 (91%) BC measurements and 149 (93%) diaries were collected. From the expected 320 urine samples, 304 (95%) were collected. The tasks noted in the diaries overlapped with information obtained from the GPS tracking of the chimney sweeps, which covered 96% of the measurement time. The PAH metabolites in urine increased during the work week. Factors believed to have positively influenced the sample collection and task documentation were the highly motivated participants and the continuous presence of trained occupational hygiene professionals during the planning of the study and throughout the measurement stage, during which they were available to inform, instruct, and address questions. In conclusion, the self-monitored protocol used in this study with chimney sweeps is a valuable and valid method that can be used to collect larger numbers of samples. This is especially valuable for occupations in which the employees are working independently and the exposure is difficult to monitor with traditional occupational hygiene methods.

Publisher

Frontiers Media SA

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3