Suction circuit flushing with chlorhexidine decreases ventilator-associated pneumonia: a quasi-experimental study

Author:

Eid Mohamed H.,Ţânţu Monica – Marilena,Latour Jos M.,Sultan Mohammed Ahmed,Kandeel Nahed Attia

Abstract

BackgroundEndotracheal suctioning of mechanically ventilated patients differs across the world. In many low and middle-income countries, endotracheal suctioning is often performed with a sterile suctioning catheter that is used for 12 h or during the length of one nursing shift. The effect of flushing multiple used endotracheal suction system with chlorhexidine after suctioning to reduce ventilator associated pneumonia (VAP) remains unclear.AimThe aim of the study is to assess the effectiveness of flushing multiple-used open endotracheal suction catheters and suctioning system with chlorhexidine gluconate 0.2% to reduce VAP in mechanically ventilated patients in a resource-limited Intensive Care Unit (ICU).MethodsDue to the difficulty of blinding the intervention for nurses who perform endo-tracheal suction procedures, we adopted a quasi-experimental method with a randomized controlled trial design. A sample of 136 ICU patients were allocated to the intervention (n = 68) or control group (n = 68) between May and November 2020. The intervention was flushing the multiple-used suction catheter and suction system with 40ml chlorhexidine gluconate 0.2% and in the control group we used normal saline to flush the catheter and suction system. The primary outcome was incidence of VAP and the cost of the flushing solutions was the secondary outcome measure.ResultsPatients in the intervention group had a lower incidence of VAP compared to patients in the control group; 15 (22.1%) vs 29 (42.6%), p = 0.01. The incidence of late-onset VAP was 26.2% in the intervention group and 49% in the control group (p = 0.026) and the early-onset VAP was 13.2% in the intervention group and 25% in the control group (p = 0.081). Chlorhexidine gluconate 0.2% reduced the cost of suction system flushing (median: 78.4 vs 300 EGP, p < 0.001).ConclusionUsing chlorhexidine gluconate 0.2% to flush multiple-used suctioning catheters after every endo-tracheal suction procedure might reduce the incidence of VAP in mechanically ventilated patients. Chlorhexidine gluconate 0.2% can be a cost-effective solution for flushing the suction circuit. Nurses working in resource-limited ICUs and using suctioning catheters multiple times might consider using chlorhexidine gluconate 0.2% instead of normal saline or distilled water when flushing the suction system.Clinical trial registrationClinicalTrials.gov, identifier NCT05206721.

Publisher

Frontiers Media SA

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3