A comparison of intraocular pressure measurement using SUOER SW-500 rebound tonometer and conventional reusable Goldmann prisms

Author:

Chaung Jia Quan,Sangapillai Thanendthire,Quilat Karen Kate,Perera Shamira

Abstract

IntroductionTo determine the agreement between intraocular pressure (IOP) measurements using conventional Goldmann applanation tonometry (GA1,2T) and SUOER SW-500 Rebound Tonometer.MethodsThis was a retrospective observational study where 205 eyes of 106 glaucoma patients had their IOPs measured by 2 fellowship trained ophthalmologists. Data were analyzed using the Bland–Altman method of differences. Correlation was measured using the Pearson coefficient.ResultsMost of our patients were Chinese (88.7%) and female (51.9%). The average age was 66.9 years. The range of IOPs as measured by GAT was 2 to 58 mm Hg. Using the Bland–Altman method to compare GAT and SUOER SW-500 Rebound Tonometer. The tonometer overestimated the IOP by 0.5 mm Hg in the right eye and underestimated it by 0.1 mm Hg in the left eye. Overall, the tonometer overestimated the IOP by 0.2 mmHg. The Tonometer IOP correlated well with GAT, with a Pearson coefficient of correlation(r) of 0.89 (p < 0.001) for the right eye and 0.86 (p < 0.001) for the left eye, respectively. In patients with GAT IOP ≥ 21 mm Hg (n = 25), the Tonometer underestimated the IOP by 2.96 mm Hg.DiscussionThe IOP measurements from the SUOER SW-500 Rebound Tonometer correlates well with the conventional GAT in measuring the IOP within normal ranges of IOP. SUOER SW-500 Rebound Tonometer may be of use, especially if the risk of transmission of infection is high considering that the probes are disposable. It is easy to use and its small size and portability makes it useful in situations where the patient is unable to be examined at the slit lamp.

Publisher

Frontiers Media SA

Reference30 articles.

1. Comparison of intraocular pressure measurements and assessment of intraobserver and interobserver reproducibility with the portable ICare rebound tonometer and Goldmann applanation tonometer in glaucoma patients;Salim;J Glaucoma,2013

2. Comparison of measurement of intraocular pressure by ICARE PRO® tonometer and Goldman applanation tonometer;Hladíková;Cesk Slov Oftalmol,2014

3. Comparison of rebound and applanation tonometry in the management of patients treated for glaucoma or ocular hypertension;Rehnman;Ophthalmic Physiol Opt,2008

4. Sources of variability in the results of applanation tonometry;Motolko;Can J Ophthalmol,1982

5. Rebound tonometry in a clinical setting. Comparison with applanation tonometry;López-Caballero;Arch Soc Esp Oftalmol,2007