Dyspnea Measurement in Acute Heart Failure: A Systematic Review and Evidence Map of Randomized Controlled Trials

Author:

Zhang Xiaoyu,Zhao Chen,Zhang Houjun,Liu Wenjing,Zhang Jingjing,Chen Zhao,You Liangzhen,Wu Yuzhuo,Zhou Kehua,Zhang Lijing,Liu Yan,Chen Jianxin,Shang Hongcai

Abstract

Background: Dyspnea is the most common presenting symptom among patients hospitalized for acute heart failure (AHF). Dyspnea relief constitutes a clinically relevant therapeutic target and endpoint for clinical trials and regulatory approval. However, there have been no widely accepted dyspnea measurement standards in AHF. By systematic review and mapping the current evidence of the applied scales, timing, and results of measurement, we hope to provide some new insights and recommendations for dyspnea measurement.Methods: PubMed, Embase, Cochrane Library, and Web of Science were searched from inception until August 27, 2020. Randomized controlled trials (RCTs) with dyspnea severity measured as the endpoint in patients with AHF were included.Results: Out of a total of 63 studies, 28 had dyspnea as the primary endpoint. The Likert scale (34, 54%) and visual analog scale (VAS) (22, 35%) were most widely used for dyspnea assessment. Among the 43 studies with detailed results, dyspnea was assessed most frequently on days 1, 2, 3, and 6 h after randomization or drug administration. Compared with control groups, better dyspnea relief was observed in the experimental groups in 21 studies. Only four studies that assessed tolvaptan compared with control on the proportion of dyspnea improvement met the criteria for meta-analyses, which did not indicate beneficial effect of dyspnea improvement on day 1 (RR: 1.16; 95% CI: 0.99–1.37; p = 0.07; I2 = 61%).Conclusion: The applied scales, analytical approaches, and timing of measurement are in diversity, which has impeded the comprehensive evaluation of clinical efficacy of potential therapies managing dyspnea in patients with AHF. Developing a more general measurement tool established on the unified unidimensional scales, standardized operation protocol to record the continuation, and clinically significant difference of dyspnea variation may be a promising approach. In addition, to evaluate the effect of experimental therapies on dyspnea more precisely, the screening time and blinded assessment are factors that need to be considered.

Funder

National Key Research and Development Program of China

National Natural Science Foundation of China

Publisher

Frontiers Media SA

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3