High-flow nasal cannula: Evaluation of the perceptions of various performance aspects among Chinese clinical staff and establishment of a multidimensional clinical evaluation system

Author:

Wen Ruoxuan,Hu Xingshuo,Wei Tengchen,Wang Kaifei,Duan Zhimei,Zhao Zhanqi,Xie Lixin,Xie Fei

Abstract

ObjectiveIn order to facilitate education for clinical users, performance aspects of the high-flow nasal cannula (HFNC) devices were evaluated in the present study. A multidimensional HFNC clinical evaluation system was established accordingly.Materials and MethodsClinical staff from Chinese hospitals were invited to participate in an online questionnaire survey. The questionnaire was mainly about the accuracy of temperature, flow rate, and oxygen concentration of HFNC, as well as its humidification capacity. We also investigated how the clinical staff of different professions made decisions on HFNC evaluation indicators. Based on the results of the questionnaire survey of clinicians with rich experience in using HFNC, the relative weights of temperature accuracy, flow velocity accuracy, oxygen concentration accuracy, and humidification ability of HFNC equipment were calculated by the AHP to establish a clinical evaluation system. Four kinds of common HFNC devices were tested and evaluated, and the clinical performance of the four kinds of HFNC devices was evaluated by the new scoring system.ResultsA total of 356 clinicians participated in and completed the questionnaire survey. To ensure the reliability of the HFNC evaluation system, we only adopted the questionnaire results of clinicians with rich experience in using HFNCs. Data from 247 questionnaires (80 doctors, 105 nurses, and 62 respiratory therapists [RTs]) were analyzed. A total of 174 participants used HFNC more than once a week; 88.71% of RTs used HFNC ≥ 1 score daily, 62.86% of nurses used HFNC ≥ 1 score daily, and 66.25% of doctors used HFNC ≥ 1 daily. There was no significant difference in the frequency of use between doctors and nurses. Finally, the relative weights of temperature accuracy (0.088), humidification capacity (0.206), flow velocity accuracy (0.311), and oxygen concentration accuracy (0.395) in the HFNC clinical evaluation system were obtained. The relative weights of clinicians with different occupations and the frequency of HFNC use were obtained. After testing four kinds of HFNC devices through the evaluation system, it was found that the four kinds of HFNC devices have different advantages in different clinical performances, and AiRVO2 has excellent performance with regard to temperature accuracy and humidification ability. HF-75A and NeoHiF-i7 are good at ensuring the stability of oxygen concentration and the accuracy of the flow velocity of the transported gas, while OH-80S is relatively stable in all aspects.ConclusionThe clinical evaluation system of HFNC is based on the weight of the experience of clinical personnel with different medical backgrounds. Although the existing practitioners have different educational backgrounds (academic qualifications, majors), our evaluation system can enhance clinical staff’s awareness of HFNC and further optimize the clinical use of HFNC.

Publisher

Frontiers Media SA

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3