Dialyzer Classification and Mortality in Hemodialysis Patients: A 3-Year Nationwide Cohort Study

Author:

Abe Masanori,Masakane Ikuto,Wada Atsushi,Nakai Shigeru,Nitta Kosaku,Nakamoto Hidetomo

Abstract

Background: Dialyzers are classified as low-flux, high-flux, and protein-leaking membrane dialyzers internationally and as types I, II, III, IV, and V based on β2-microglobulin clearance rate in Japan. Type I dialyzers correspond to low-flux membrane dialyzers, types II and III to high-flux membrane dialyzers, and types IV and V to protein-leaking membrane dialyzers. Here we aimed to clarify the association of dialyzer type with mortality.Methods: This nationwide retrospective cohort study analyzed data from the Japanese Society for Dialysis Therapy Renal Data Registry from 2010 to 2013. We enrolled 238,321 patients on hemodialysis who were divided into low-flux, high-flux, and protein-leaking groups in the international classification and into type I to V groups in the Japanese classification. We assessed the associations of each group with 3-year all-cause mortality using Cox proportional hazards models and performed propensity score matching analysis.Results: By the end of 2013, 55,308 prevalent dialysis patients (23.2%) had died. In the international classification subgroup analysis, the hazard ratio (95% confidence interval) was significantly higher in the low-flux group [1.12 (1.03–1.22), P = 0.009] and significantly lower in the protein-leaking group [0.95 (0.92–0.98), P = 0.006] compared with the high-flux group after adjustment for all confounders. In the Japanese classification subgroup analysis, the hazard ratios were significantly higher for types I [1.10 (1.02–1.19), P = 0.015] and II [1.10 (1.02–1.39), P = 0.014] but significantly lower for type V [0.91 (0.88–0.94), P < 0.0001] compared with type IV after adjustment for all confounders. These significant findings persisted after propensity score matching under both classifications.Conclusions: Hemodialysis using protein-leaking dialyzers might reduce mortality rates. Furthermore, type V dialyzers are superior to type IV dialyzers in hemodialysis patients.

Publisher

Frontiers Media SA

Subject

General Medicine

Reference42 articles.

1. β2 microglobulin amyloidosis: an update 30 years later;Jadoul;Nephrol Dial Transplant.,2016

2. Beta 2-microglobulin levels in patients with renal insufficiency;Acchiardo;Am J Kidney Dis.,1989

3. Reappraisal of serum beta2-microglobulin as marker of GFR;Bianchi;Ren Fail.,2001

4. Serum low-molecular-weight proteins in haemodialysis patients: effect of residual renal function;Brown;Nephrol Dial Transplant.,1988

5. Novel filtration markers as predictors of all-cause and cardiovascular mortality in US adults;Foster;Am J Kidney Dis.,2013

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3