Validation of a fully automated chemiluminescent immunoassay for cattle serum and plasma progesterone measurement

Author:

Megahed Ameer A.,Jones Kristi L.,Bisinotto Rafael S.,Chebel Ricardo C.,Galvão Klibs N.,Chan Ann M.,Bittar João H. J.

Abstract

IntroductionMonitoring circulating progesterone concentration ([P4]) is an important component of basic and applied reproduction research and clinical settings. IMMULITE® 2000 XPi (Siemens Healthineers, Cary, NC) is a newly upgraded fully automated immunoassay system marketed for human use to measure concentrations of different measurands including P4.ObjectivesOur objective was therefore to characterize the analytical performance of the IMMULITE® 2000 XPi P4 immunoassay (IPI) across the reportable range in serum and plasma of cattle.MethodsThe IPI validation protocols included characterization of the method linearity, within-run, and between-run precision through calculation of the coefficient of variation (CV). The method accuracy was assessed through the calculation of the spiking-recovery (SR) bias across the reportable range (0.2–40.0 ng/mL). Passing–Bablok regression and Bland-Altman plots were used to determine the interlaboratory bias for two laboratories. Three types of observed total error (TEo) were calculated based on the considered type of bias, TEoSR (spiking-recovery), TEoRB (range-based bias), and TEoAB (average-based bias).ResultsThe IPI was linearly related to the true value (R2 = 0.997) across the reportable range. The within-run and between-run precision (CV%) of the IPI for both serum and plasma [P4] of clinical relevance (1, 2, 5, and 10 ng/mL) were <5 and <10%, respectively. The TEo reported here for serum and plasma at [P4] of 1 and 5 ng/mL was ~20 and 25%, respectively. Of interest, the three types of TEo were relatively similar regardless of the considered bias.ConclusionsWe concluded that the automated IPI provides a precise, accurate, reliable, and safe method for measuring [P4] in both serum and plasma of cattle. Consistent with the manufacturer's recommendations, the serum matrix is more accurate than plasma.

Publisher

Frontiers Media SA

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3