Use of Citrated Whole Blood for Point-of-Care Viscoelastic Coagulation Testing in Dogs

Author:

York Whitney,Smith M. Ryan,Liu Chin-Chi

Abstract

BackgroundA new, portable bedside coagulation monitor (VCM Vet) has provided a user-friendly, cartridge-based method to perform viscoelastic testing. However, the use of native whole blood limits the time to analyze the sample to minutes. The objective of this study is to assess whether citrated whole blood can be utilized with the cartridge-based system and whether the results are comparable to those of native whole blood. A secondary objective is to assess the viability of citrated whole blood results after up to 4 hours of resting.MethodsThe study population consisted of 10 healthy mixed breed dogs. Whole blood samples were collected via jugular venipuncture. Blood was immediately transferred to the VCM test cartridge for native whole blood control group analysis per the manufacturer's instructions, and the remainder was used to fill two 3.2% sodium citrate vacutainer tubes. Test group analysis was performed on samples from each tube concurrently after a rest period of 30 min (baseline), 2 h, and 4 h. Citrated whole blood samples were recalcified for analysis immediately prior to introduction into the test cartridge. Data was recorded for all reported parameters. Results from the citrate groups were compared to the control group and to the citrated baseline to assess for differences. Overall results were compared using mixed ANOVA models. Where found, specific differences were evaluated using Tukey's test. Within-sample variation was investigated and reported as median (range). A p < 0.05 was considered significant.ResultsSamples were obtained for a total of 10 control runs and 20 citrated whole blood runs. Comparison of controls to the citrated test groups revealed significant differences in CT (p < 0.001) and MCF (p < 0.002). There were no significant differences between test groups compared to citrated baselines for any parameter. Selected median coefficients of variation were 6.8% (0–68.8%) for CT, 2.4% (0–19.46%) for alpha angle, 3.2% (0–27.4%) for MCF, and 0% (0–16.3%) for 45-min LY45.ConclusionCitrated whole blood samples can be used with the VCM Vet device; however, new reference intervals for use with citrated whole blood will be required. Results using citrated whole blood samples are not significantly different from baseline after up to 4 h of resting.

Publisher

Frontiers Media SA

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3