Author:
Mitropoulou Athanasia,Lehmann Hendrik,Heier Evelyn M.,Schneider Matthias,Hassdenteufel Esther
Abstract
A 4-year-old female Boxer was referred for renal replacement therapy 2 days after observed grape ingestion. An 11-French dual-lumen dialysis catheter was placed into the right jugular vein and continuous renal replacement therapy was initiated for 66 h. Afterwards the patient received enoxaparin subcutaneously as a thromboprophylaxis. Four hours after removal of the dialysis catheter the patient developed severe dyspnea with hypercapnia and signs of hemorrhagic shock. Bedside ultrasound and X-rays of the thorax revealed a soft tissue opacity dorsally of the trachea, located in the mediastinum. The findings were consistent with mediastinal bleeding and hematoma formation. Blood gas examination indicated hypoventilation. The dog was managed conservatively with multiple blood transfusions and mechanical ventilation. The patient survived to discharge, and the hematoma was fully absorbed in the radiographs after 17 days. Patients with impaired kidney function should receive individualized enoxaparin dosage adjusted to anti-Xa levels and should be strictly monitored for complications. Mediastinal hemorrhage and hematoma formation should be considered as a potential complication in patients receiving a jugular vein catheter.
Funder
Justus Liebig Universität Gießen
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献