Development, Validation, and Reliability of a Sedation Scale in Horses (EquiSed)

Author:

Oliveira Alice Rodrigues de,Gozalo-Marcilla Miguel,Ringer Simone Katja,Schauvliege Stijn,Fonseca Mariana Werneck,Trindade Pedro Henrique Esteves,Puoli Filho José Nicolau Prospero,Luna Stelio Pacca Loureiro

Abstract

The lack of standardization of sedation scales in horses limits the reproducibility between different studies. This prospective, randomized, blinded, horizontal and controlled trial aimed to validate a scale for sedation in horses (EquiSed). Seven horses were treated with intravenous detomidine in low/high doses alone (DL 2.5 μg/kg + 6.25 μg/kg/h; DH 5 μg/kg +12.5 μg/kg/h) or associated with methadone (DLM and DHM, 0.2 mg/kg + 0.05 mg/kg/h) and with low (ACPL 0.02 mg/kg) or high (ACPH 0.09 mg/kg) doses of acepromazine alone. Horses were filmed at (i) baseline (ii) peak, (iii) intermediate, and (iv) end of sedation immediately before auditory, visual and pressure stimuli were applied and postural instability evaluated for another study. Videos were randomized and blindly evaluated by four evaluators in two phases with 1-month interval. Intra- and interobserver reliability of the sum of EquiSed (Intraclass correlation coefficient) ranged between 0.84–0.94 and 0.45–0.88, respectively. The criterion validity was endorsed by the high Spearman correlation between the EquiSed and visual analog (0.77), numerical rating (0.76), and simple descriptive scales (0.70), and average correlation with head height above the ground (HHAG) (−0.52). The Friedman test confirmed the EquiSed responsiveness over time. The principal component analysis showed that all items of the scale had a load factor ≥ 0.50. The item-total Spearman correlation for all items ranged from 0.3 to 0.5, and the internal consistency was good (Cronbach's α = 0.73). The area under the curve of EquiSed HHAG as a predictive diagnostic measure was 0.88. The sensitivity of the EquiSed calculated according to the cut-off point (score 7 of the sum of the EquiSed) determined by the receiver operating characteristic curve, was 96% and specificity was 83%. EquiSed has good intra- and interobserver reliabilities and is valid to evaluate tranquilization and sedation in horses.

Publisher

Frontiers Media SA

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3