Author:
Missiaggia M.,Pierobon E.,Castelluzzo M.,Perinelli A.,Cordoni F.,Centis Vignali M.,Borghi G.,Bellinzona E. V.,Scifoni E.,Tommasino F.,Monaco V.,Ricci L.,Boscardin M.,La Tessa Chiara
Abstract
In microdosimetry, lineal energies y are calculated from energy depositions ϵ inside the microdosimeter divided by the mean chord length, whose value is based on geometrical assumptions on both the detector and the radiation field. This work presents an innovative two-stages hybrid detector (HDM: hybrid detector for microdosimetry) composed by a tissue equivalent proportional counter and a silicon tracker made of 4 low gain avalanche diode. This design provides a direct measurement of energy deposition in tissue as well as particles tracking with a submillimeter lateral spatial resolution. The data collected by the detector allow to obtain the real track length traversed by each particle in the tissue equivalent proportional counter and thus estimates microdosimetry spectra without the mean chord length approximation. Using Geant4 toolkit, we investigated HDM performances in terms of detection and tracking efficiencies when placed in water and exposed to protons and carbon ions in the therapeutic energy range. The results indicate that the mean chord length approximation underestimate particles with short track, which often are characterized by a high energy deposition and thus can be biologically relevant. Tracking efficiency depends on the low gain avalanche diode configurations: 34 strips sensors have a higher detection efficiency but lower spatial resolution than 71 strips sensors. Further studies will be performed both with Geant4 and experimentally to optimize the detector design on the bases of the radiation field of interest.The main purpose of HDM is to improve the assessment of the radiation biological effectiveness via microdosimetric measurements, exploiting a new definition of the lineal energy (yT), defined as the energy deposition ϵ inside the microdosimeter divided by the real track length of the particle.
Subject
Physical and Theoretical Chemistry,General Physics and Astronomy,Mathematical Physics,Materials Science (miscellaneous),Biophysics
Reference33 articles.
1. Silicon microdosimetry;Agosteo;Radiat Protect Dosim,2011
2. Novel detectors for silicon based microdosimetry, their concepts and applications;Rosenfeld;Nucl Instrum Methods Phys Res Sect A Accel Spectrom Detect Assoc Equip,2016
3. Evolution of diamond based microdosimetry;Davis,2019
4. A device for the measurement of dose as a function of specific ionization;Rossi;Radiology,1955
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献