An MMC based HVDC system with optimized AC fault ride-through capability and enhanced circulating current suppression control
-
Published:2023-05-24
Issue:
Volume:11
Page:
-
ISSN:2296-598X
-
Container-title:Frontiers in Energy Research
-
language:
-
Short-container-title:Front. Energy Res.
Author:
Badar Jahangeer,Akhtar Faheem,Kumar Dileep,Munir Hafiz Mudassir,Ali Khawaja Haider,Alsaif Faisal,Alsulamy Sager
Abstract
Modular multilevel converter (MMC) is a proven technology for HVDC applications due to its salient features such as modularity and excellent power quality. To ensure best possible grid support, recent grid codes require incorporating fault ride-through (FRT) strategies so that HVDC converter stations remain connected and maintain reliable operation under various symmetrical and asymmetrical AC faults. In this paper, a communication-free enhanced fault ride-through technique without the need of DC chopper has been proposed. The proposed FRT strategy ensures quick post fault recovery operation and can effectively manage DC link and capacitor voltages within safe limits. Along with proposed FRT strategy, in order to avoid high circulating current (CC) inside an MMC, this paper has proposed an optimal circulating current control approach based on proportional resonant and PI controllers in an abc reference frame. The suggested technique lowers the ripple in capacitor voltages while reducing the magnitude of the CC. Under both balanced and unbalanced ac grid conditions, the ripple in the dc link voltage is also reduced without the use of dual synchronous reference frame or any additional controllers. Simulation results confirm the effectiveness of the proposed FRT and CC suppression techniques for a 580-kV, 850-MW MMC-based HVDC system.
Publisher
Frontiers Media SA
Subject
Economics and Econometrics,Energy Engineering and Power Technology,Fuel Technology,Renewable Energy, Sustainability and the Environment
Reference58 articles.
1. AC fault ride-through capability of a VSC-HVDC transmission systems;Adam,2010
2. Power quality improvement in HVDC MMC with modified nearest level control in real-time HIL based setup;Ali;IEEE Access,2020
3. An enhanced fault ride-through capability for MTDC systems using vector current control and inherent energy of submodules of MMC;Ansari,2022
4. Control and protection of MMC-based HVDC systems: A review;Chandio;Energy Rep.,2023
5. A comprehensive AC fault ride-through strategy for HVDC link with serial-connected LCC-VSC hybrid inverter;Cheng;CSEE J. Power Energy Syst.,2021