Refined risk assessment and differentiated protection of lightning damage in distribution network lines considering the underlying surface environment

Author:

Wan Ziyang,Fu Lixiang,Du Zhenchuan,Chen Zhigang,Liu Chao,Zhu Yi,Ma Xiaoxin

Abstract

The distribution line is widely distributed and the span of pole-towers is small. However, the existing lightning positioning system has limited positioning accuracy, and the lightning strike coordinates it locates have certain deviations for the distribution network. The lightning hazard risk divided by lightning density is not sufficient to support the differentiated lightning protection transformation of the distribution network. The environment of the underlying surface where the pole-tower is located has a significant impact on lightning activity, so this paper combines terrain, climate, lightning current characteristics, and historical lightning trip data to finely evaluate the lightning risk level in the distribution line pole-tower area. This paper provides a detailed analysis of the relationship between different underlying surface environments and lightning current characteristics and utilizes the entropy weight method to construct a comprehensive lightning disaster risk index, then evaluates the risk level of lightning disaster in different regions, and corrects it through lightning fault data. Overlaying the risk level of the area and the distribution map of the pole-tower foundation coordinates, it will obtain the distribution of lightning hazard-pregnant risk at the pole-tower area, which would contribute to guiding the differentiated lightning protection transformation of the line. Compared to traditional unified lightning protection renovation methods, differentiated lightning protection methods that integrate factors such as pole-tower structure, wire type, and lightning risk level can achieve significant lightning protection effects at a lower economic cost. Taking Nanchang City as an example, risk assessment and lightning protection renovation were conducted on 21 distribution lines. The average number of lightning trips per year is 55 before the renovation, but it is only 4 after the renovation, which the number of lightning trips significantly reduce. This verifies the effectiveness of using lightning hazard-pregnant assessment results to guide differentiated lightning protection methods.

Publisher

Frontiers Media SA

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3