Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve

Author:

Tanade Cyrus,Chen S. James,Leopold Jane A.,Randles Amanda

Abstract

BackgroundPersonalized hemodynamic models can accurately compute fractional flow reserve (FFR) from coronary angiograms and clinical measurements (FFRbaseline), but obtaining patient-specific data could be challenging and sometimes not feasible. Understanding which measurements need to be patient-tuned vs. patient-generalized would inform models with minimal inputs that could expedite data collection and simulation pipelines.AimsTo determine the minimum set of patient-specific inputs to compute FFR using invasive measurement of FFR (FFRinvasive) as gold standard.Materials and MethodsPersonalized coronary geometries (N=50) were derived from patient coronary angiograms. A computational fluid dynamics framework, FFRbaseline, was parameterized with patient-specific inputs: coronary geometry, stenosis geometry, mean arterial pressure, cardiac output, heart rate, hematocrit, and distal pressure location. FFRbaseline was validated against FFRinvasive and used as the baseline to elucidate the impact of uncertainty on personalized inputs through global uncertainty analysis. FFRstreamlined was created by only incorporating the most sensitive inputs and FFRsemi-streamlined additionally included patient-specific distal location.ResultsFFRbaseline was validated against FFRinvasive via correlation (r=0.714, p<0.001), agreement (mean difference: 0.01±0.09), and diagnostic performance (sensitivity: 89.5%, specificity: 93.6%, PPV: 89.5%, NPV: 93.6%, AUC: 0.95). FFRsemi-streamlined provided identical diagnostic performance with FFRbaseline. Compared to FFRbaseline vs. FFRinvasive, FFRstreamlined vs. FFRinvasive had decreased correlation (r=0.64, p<0.001), improved agreement (mean difference: 0.01±0.08), and comparable diagnostic performance (sensitivity: 79.0%, specificity: 90.3%, PPV: 83.3%, NPV: 87.5%, AUC: 0.90).ConclusionStreamlined models could match the diagnostic performance of the baseline with a full gamut of patient-specific measurements. Capturing coronary hemodynamics depended most on accurate geometry reconstruction and cardiac output measurement.

Funder

Coulter Foundation

NSF GRFP

American Heart Association

NHLBI

NSF

Publisher

Frontiers Media SA

Subject

Management Science and Operations Research,Mechanical Engineering,Energy Engineering and Power Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3