Cardiac output monitoring with pulmonary versus trans-cardiopulmonary thermodilution in left ventricular assist devices: Interchangeable methods?

Author:

Quintana-Villamandos Begoña,Barranco Mónica,Fernández Ignacio,Ruiz Manuel,Del Cañizo Juan Francisco

Abstract

Cardiac output (CO) measurement is mandatory in patients with left ventricular assist devices (LVADs). Thermodilution with pulmonary artery catheter (PAC) remains the clinical gold standard to measure CO in these patients, however it is associated with several complications. Therefore, the agreement between PAC and new, minimally invasive monitoring methods in LVAD needs to be further investigated. The aim of this study was to assess the accuracy and reliability of transpulmonary thermodilution with a PiCCO2 monitor compared with pulmonary artery thermodilution with PAC in a LVAD. Continuous-flow LVADs were implanted in six mini-pigs to assist the left ventricle. We studied two methods of measuring CO—intermittent transpulmonary thermodilution (COTPTD) by PiCCO2 and intermittent pulmonary artery thermodilution by CAP, standard technique (COPTD)—obtained in four consecutive moments of the study: before starting the LVAD (basal moment), and with the LVAD started in normovolemia, hypervolemia (fluid overloading) and hypovolemia (shock hemorrhage). A total of 72 paired measurements were analysed. At the basal moment, COTPTD and COPTD were closely correlated (r2 = 0.89), with a mean bias of −0.085 ± 0.245 L/min and percentage error of 16%. After 15 min of partial support LVAD, COTPTD and COPTD were closely correlated (r2 = 0.79), with a mean bias of −0.040 ± 0.417 L/min and percentage error of 26%. After inducing hypervolemia, COTPTD and COPTD were closely correlated (r2 = 0.78), with a mean bias of −0.093 ± 0.339 L/min and percentage error of 13%. After inducing hypovolemia, COTPTD and COPTD were closely correlated (r2 = 0.76), with a mean bias of −0.045 ± 0.281 L/min and percentage error of 28%. This study demonstrates a good agreement between transpulmonary thermodilution by PiCCO monitor and pulmonary thermodilution by PAC in the intermittent measurement of CO in a porcine model with a continuous-flow LVAD.

Publisher

Frontiers Media SA

Subject

Physiology (medical),Physiology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3