The Validity of the 2-Point Method for Assessing the Force-Velocity Relationship of the Knee Flexors and Knee Extensors: The Relevance of Distant Force-Velocity Testing

Author:

Sašek Matic,Mirkov Dragan M.,Hadžić Vedran,Šarabon Nejc

Abstract

Over the past decade, force-velocity (F-v) profiling has emerged as a promising tool for assessing neuromuscular capacity to design individually tailored interventions in diverse populations. To date, a limited number of studies have addressed the optimization of the linear method for measuring F-v profiles of single-joint isokinetic movements. We aimed to simplify the measurement of knee extension (KE) and knee flexion (KF) isokinetic tasks by evaluating the most appropriate combination of two velocities (i.e., the 2-point method). Twenty-two healthy participants (11 males and 11 females) were included in the study. Isokinetic peak torque was measured at nine angular velocities (30-60-90-120-150-180-210-240-300°/s) and under isometric conditions (at 150° and 120° of KF for KE, and KF, respectively). Maximal theoretical force (F0), maximal theoretical velocity (v0), slope of the relationship (Sfv) and maximal theoretical power (Pmax) were derived from the linear F-v profiles of KE and KF and compared between the 9-point method and all possible combinations (36 in total) of the 2-point methods. The F-v profiles obtained from nine points were linear for KE (R2 = 0.95; 95% CI = 0.94–0.96) and KF (R2 = 0.93; 95% CI = 0.90–0.95), with F0 underestimating isometric force. Further analyses revealed great to excellent validity (range: ICCs = 0.89–0.99; CV = 2.54%–4.34%) and trivial systematic error (range: ES = −0.11–0.24) of the KE 2-point method when force from distant velocities (30°/s, 60°/s or 90°/s combined with 210°/s, 240°/s or 300°/s) was used. Similarly, great to excellent validity and trivial systematic error of the KF 2-point method for F0 and Pmax (range: ICC = 0.90–0.96; CV = 2.94%–6.38%; ES = −0.07–0.14) were observed when using the previously described combinations of velocities. These results suggest that practitioners should consider using more distant velocities when performing simplified isokinetic 2-point single-joint F-v profiling. Furthermore, the F-v profile has the potential to differentiate between the mechanical properties of knee extensors and flexors and could therefore serve as a potential descriptor of performance.

Publisher

Frontiers Media SA

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3