Treatment Site Does Not Affect Changes in Pulse Wave Velocity but Treatment Length and Device Selection Are Associated With Increased Pulse Wave Velocity After Thoracic Endovascular Aortic Repair

Author:

Hori Daijiro,Fujimori Tomonari,Kusadokoro Sho,Yamamoto Takahiro,Kimura Naoyuki,Yamaguchi Atsushi

Abstract

Background: Endovascular treatment of aortic aneurysm is associated with an increase in pulse wave velocity (PWV) after surgery. However, the effect of different types of endovascular devices on PWV at different sites of the thoracic aorta remains unclear.Objectives: The purposes of this study were (1) to investigate the changes in PWV after endovascular treatment of thoracic aortic aneurysm; (2) to evaluate whether there is a difference in the changes in PWV at different treatment sites; and (3) to evaluate the effect of treatment length on changes in PWV.Methods: From July 2008 to July 2021, 276 patients underwent endovascular treatment of the true thoracic aortic aneurysm. Of these patients, 183 patients who underwent preoperative and postoperative PWV measurement within 1 year of surgery were included in the study. The treatment length index was calculated by treatment length divided by the height of the patients.Results: Five different types of endovascular devices were used (Najuta, Kawasumi Laboratories, Inc., Tokyo, Japan; TAG, W.L. Gore & Associates, Inc., AZ, USA; Relay, Bolton Medical, Inc., FL, USA; Talent/Valiant, Medtronic, MN, USA; and Zenith, Cook Medical, IN, USA). There was no significant change in PWV in patients receiving Najuta (Before: 2,040 ± 346.8 cm/s vs. After: 2,084 ± 390.5 cm/s, p = 0.14). However, a significant increase was observed in other devices: TAG (Before: 2,090 ± 485.9 cm/s vs. After: 2,300 ± 512.1 cm/s, p = 0.025), Relay (Before: 2,102 ± 465.3 cm/s vs. After: 2,206 ± 444.4 cm/s, p = 0.004), Valiant (Before: 1,696 ± 330.2 cm/s vs. After: 2,186 ± 378.7 cm/s, p < 0.001), and Zenith (Before: 2,084 ± 431.7 cm/s vs. After: 2,321 ± 500.6 cm/s, p < 0.001). There was a significant increase in PWV in patients treated from aortic arch (Before: 2,006 ± 333.7 cm/s vs. After: 2,132 ± 423.7 cm/s, p < 0.001) and patients treated from descending thoracic aorta (Before: 2,116 ± 460.9 cm/s vs. After: 2,292 ± 460.9 cm/s, p < 0.001). Multivariate analysis showed that treatment site was not an independent factor associated with changes in PWV. However, Najuta (Coef −219.43, 95% CI −322.684 to −116.176, p < 0.001) and treatment index (Coef 147.57, 95% CI 24.826 to 270.312, p = 0.019) were independent factors associated with changes in PWV.Conclusion: Najuta did not show a significant increase in PWV, while other commercially available devices showed a significant increase. The treatment site did not have a different effect on PWV. However, the treatment length was an independent factor associated with an increase in PWV.

Publisher

Frontiers Media SA

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3