Methodological heterogeneity biases physical activity metrics derived from the Actigraph GT3X in multiple sclerosis: A rapid review and comparative study

Author:

Polhemus Ashley,Haag Christina,Sieber Chloé,Sylvester Ramona,Kool Jan,Gonzenbach Roman,von Wyl Viktor

Abstract

BackgroundPhysical activity (PA) is reduced in persons with multiple sclerosis (MS), though it is known to aid in symptom and fatigue management. Methods for measuring PA are diverse and the impact of this heterogeneity on study outcomes is unclear. We aimed to clarify this impact by comparing common methods for deriving PA metrics in MS populations.MethodsFirst, a rapid review of existing literature identified methods for calculating PA in studies which used the Actigraph GT3X in populations with MS. We then compared methods in a prospective study on 42 persons with MS [EDSS 4.5 (3.5–6)] during a voluntary course of inpatient neurorehabilitation. Mixed-effects linear regression identified methodological factors which influenced PA measurements. Non-parametric hypothesis tests, correlations, and agreement statistics assessed overall and pairwise differences between methods.ResultsIn the rapid review, searches identified 421 unique records. Sixty-nine records representing 51 eligible studies exhibited substantial heterogeneity in methodology and reporting practices. In a subsequent comparative study, multiple methods for deriving six PA metrics (step count, activity counts, total time in PA, sedentary time, time in light PA, time in moderate to vigorous PA), were identified and directly compared. All metrics were sensitive to methodological factors such as the selected preprocessing filter, data source (vertical vs. vector magnitude counts), and cutpoint. Additionally, sedentary time was sensitive to wear time definitions. Pairwise correlation and agreement between methods varied from weak (minimum correlation: 0.15, minimum agreement: 0.03) to perfect (maximum correlation: 1.00, maximum agreement: 1.00). Methodological factors biased both point estimates of PA and correlations between PA and clinical assessments.ConclusionsMethodological heterogeneity of existing literature is high, and this heterogeneity may confound studies which use the Actigraph GT3X. Step counts were highly sensitive to the filter used to process raw accelerometer data. Sedentary time was particularly sensitive to methodology, and we recommend using total time in PA instead. Several, though not all, methods for deriving light PA and moderate to vigorous PA yielded nearly identical results. PA metrics based on vertical axis counts tended to outperform those based on vector magnitude counts. Additional research is needed to establish the relative validity of existing methods.

Publisher

Frontiers Media SA

Subject

General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3