A novel image integration technology mapping system significantly reduces radiation exposure during ablation for a wide spectrum of tachyarrhythmias in children

Author:

He Jiang,Yi Zhang,Meiting Li,Huiming Zhou,Jinhao Li,Danlei Chen,Xiaomei Li

Abstract

ObjectiveRadiofrequency catheter ablation (RFCA) has evolved into an effective and safe technique for the treatment of tachyarrhythmia in children. Concerns about children and involved medical staff being exposed to radiation during the procedure should not be ignored. “Fluoroscopy integrated 3D mapping”, a new 3D non-fluoroscopic navigation system software (CARTO Univu Module) could reduce fluoroscopy during the procedure. However, there are few studies about the use of this new technology on children. In the present study, we analyzed the impact of the CARTO Univu on procedural safety and fluoroscopy in a wide spectrum of tachyarrhythmias as compared with CARTO3 alone.MethodsThe data of children with tachyarrhythmias who underwent RFCA from June 2018 to December 2021 were collected. The CARTO Univu was used for mapping and ablation in 200 cases (C3U group) [boys/girls (105/95), mean age (6.8 ± 3.7 years), mean body weight (29.4 ± 7.9 kg)], and the CARTO3 was used in 200 cases as the control group (C3 group) [male/female (103/97), mean age (7.2 ± 3.9 years), mean body weight (32.3 ± 19.0 kg)]. The arrhythmias were atrioventricular reentrant tachycardia (AVRT, n = 78), atrioventricular node reentrant tachycardia (AVNRT, n = 35), typical atrial flutter (AFL, n = 12), atrial tachycardia (AT, n = 20) and ventricular arrhythmias [VAs, premature ventricular complexes or ventricular tachycardia, n = 55].Results① There was no significant difference in the acute success rate, recurrence rate, and complication rate between the C3 and C3U groups [(94.5% vs. 95.0%); (6.3% vs. 5.3%); and (2.0% vs. 1.5%); P > 0.05]. ② The CARTO Univu reduced radiation exposure: fluoroscopy time: AVRT C3: 8.5 ± 7.2 min vs. C3U: 4.5 ± 2.9 min, P < 0.05; AVNRT C3: 10.7 ± 3.2 min vs. C3U: 4.3 ± 2.6 min, P < 0.05; AT C3: 15.7 ± 8.2 min vs. C3U: 4.5 ± 1.7 min, P < 0.05; AFL C3: 8.7 ± 3.2 min vs. C3U: 3.7 ± 2.7 min, P < 0.05; VAs C3: 7.7 ± 4.2 min vs. C3U: 3.9 ± 2.3 min, P < 0.05. Corresponding to the fluoroscopy time, the fluoroscopy dose was also reduced significantly. ③ In the C3U group, the fluoroscopy during VAs ablation was lower than that of other arrhythmias (P < 0.05).ConclusionThe usage of the “novel image integration technology” CARTO Univu might be safe and effective in RFCA for a wide spectrum of tachyarrhythmias in children, which could significantly reduce fluoroscopy and has a more prominent advantage for VAs ablation.

Publisher

Frontiers Media SA

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3