Comparison of Two-Step Transient Evoked Otoacoustic Emissions and One-Step Automated Auditory Brainstem Response for Universal Newborn Hearing Screening Programs in Remote Areas of China

Author:

Sheng Haibin,Zhou Qian,Wang Qixuan,Yu Yun,Liu Lihua,Liang Meie,Zhou Xueyan,Wu Hao,Tang Xiangrong,Huang Zhiwu

Abstract

Objective: To compare the hearing screening results of two-step transient evoked otoacoustic emissions (TEOAE) and one-step automatic auditory brainstem response (AABR) in non-risk newborns, and to explore a more suitable hearing screening protocol for infants discharged within 48 h after birth in remote areas of China.Methods: To analyze the age effect on pass rate for hearing screening, 2005 newborns were divided into three groups according to screening time after birth: <24, 24–48, and 48–72 h. All subjects received TEOAE + AABR test as first hearing screen, and those who failed in any test were rescreened with TEOAE + AABR at 6 weeks after birth. The first screening results of AABR and TEOAE were compared among the three groups. The results of two-step TEOAE screening and one-step AABR screening were compared for newborns who were discharged within 48 h. The time spent on screening was recorded for TEOAE and AABR.Results: The pass rate of TEOAE and AABR increased significantly with the increase of first screening time (P < 0.05), and the false positive rate decreased significantly with the increase of first screening time (P < 0.05). The failure rate of first screening of AABR within 48 h was 7.31%, which was significantly lower than that of TEOAE (9.93%) (P < 0.05). The average time spent on AABR was 12.51 ± 6.36 min, which was significantly higher than that of TEOAE (4.05 ± 1.56 min, P < 0.05). The failure rate of TEOAE two-step screening was 1.59%, which was significantly lower than one-step AABR.Conclusions: Compared with TEOAE, AABR screening within 48 h after birth can reduce the failure rate and false positive rate of first screening. However, compared with TEOAE two-step screening, one-step AABR screening has higher referral rate for audiological diagnosis. In remote areas of China, especially in hospitals with high delivery rate, one-step AABR screening is not feasible, and two-step TEOAE screening protocol is still applicable to UNHS screening as more and more infants discharged within 48 h after birth.

Publisher

Frontiers Media SA

Subject

Pediatrics, Perinatology and Child Health

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3