No association between thickening fraction of the diaphragm and extubation success in ventilated children

Author:

Duyndam Anita,Smit Joke,Houmes Robert Jan,Heunks Leo,Molinger Jeroen,IJland Marloes,van Rosmalen Joost,van Dijk Monique,Tibboel Dick,Ista Erwin

Abstract

IntroductionIn mechanically ventilated adults, thickening fraction of diaphragm (dTF) measured by ultrasound is used to predict extubation success. Whether dTF can also predict extubation success in children is unclear.AimTo investigate the association between dTF and extubation success in children. Second, to assess diaphragm thickness during ventilation and the correlation between dTF, diaphragm thickness (Tdi), age and body surface.MethodProspective observational cohort study in children aged 0–18 years old with expected invasive ventilation for >48 h. Ultrasound was performed on day 1 after intubation (baseline), day 4, day 7, day 10, at pre-extubation, and within 24 h after extubation. Primary outcome was the association between dTF pre-extubation and extubation success. Secondary outcome measures were Tdi end-inspiratory and Tdi end-expiratory and atrophy defined as <10% decrease of Tdi end-expiratory versus baseline at pre-extubation. Correlations were calculated with Spearman correlation coefficients. Inter-rater reliability was calculated with intraclass correlation (ICC).ResultsFifty-three patients, with median age 3.0 months (IQR 0.1–66.0) and median duration of invasive ventilation of 114.0 h (IQR 55.5–193.5), were enrolled. Median dTF before extubation with Pressure Support 10 above 5 cmH2O was 15.2% (IQR 9.7–19.3). Extubation failure occurred in six children, three of whom were re-intubated and three then received non-invasive ventilation. There was no significant association between dTF and extubation success; OR 0.33 (95% CI; 0.06–1.86). Diaphragmatic atrophy was observed in 17/53 cases, in three of extubation failure occurred. Children in the extubation failure group were younger: 2.0 months (IQR 0.81–183.0) vs. 3.0 months (IQR 0.10–48.0); p = 0.045. At baseline, pre-extubation and post-extubation there was no significant correlation between age and BSA on the one hand and dTF, Tdi- insp and Tdi-exp on the other hand. The ICC representing the level of inter-rater reliability between the two examiners performing the ultrasounds was 0.994 (95% CI 0.970–0.999). The ICC of the inter-rater reliability between the raters in 36 paired assessments was 0.983 (95% CI 0.974–0.990).ConclusionThere was no significant association between thickening fraction of the diaphragm and extubation success in ventilated children.

Publisher

Frontiers Media SA

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3