This contribution presents a Lyapunov-based controller and observer design method to achieve an effective design process for more dedicated closed-loop dynamics, i.e., a maximal flexibility in an observer-based controller design with a large consistency in desired and achieved closed-loop system dynamics is intended. The proposed, pragmatic approach enhances the scope for controller and observer design by using local instead of global Lyapunov functions, beneficial for systems with widely spaced pole locations. Within this contribution, the proposed design approach is applied to the complex control design task of wind turbine control. As the mechanical loads that affect the wind turbine components are very sensitive to the closed-loop system dynamic, a maximum flexibility in the control design is necessary for an appropriate wind turbine controller performance. Therefore, the implication of the local Lyapunov approach for an effective control design in the Takagi-Sugeno framework is discussed based on the sensitivity of the closed-loop pole locations and resulting mechanical loads to a variation of the design parameters.
Reference41 articles.
1. Wind Turbine Control Systems
2. The design of closed loop controllers for wind turbines;Bossanyi;Wind Energy (Chichester).,2000
3. Linear Matrix Inequalities in System and Control Theory
4. H∞ design with Pole placement constraints: an LMI approach;Chilali;IEEE Trans. Autom. Contr.,1996
5. Assessment criteria for the mechanical loads of wind turbines applied to the example of active power control, s. 1-7, berlin, Germany;Clemens,2020