Biomechanical comparisons of F.E.R.I. techniques with different type of intramedullary screws fixation for Jones fractures

Author:

Su Kuo-Chih,Yen Yu-Chun,Wang Chun-Hsiang,Wang Yi-Lun,Wang Shun-Ping

Abstract

Introduction: Jones fractures frequently fail to unite, and adequate fixation stability is crucial. This study aimed to elucidate the biomechanical stability of various intramedullary screw fixation constructs.Methods: Jones fracture model over the proximal 5th metatarsal of artificial bone was created in all specimens. Six groups were divided based on varied screw constructs with different screw lengths, either 30 or 40 mm, including cannulated screws—C30 and C40 groups, one high-resistance suture combined with intramedullary cannulated screws (F.E.R.I. technique)—CF30 and CF40 groups, and second-generation headless compression screws (SG-HCS) —HL30 and HL40 groups. Mechanical testing was conducted sequentially, and the maximal force (N) and stiffness (N/mm) of all constructs were recorded.Results: The maximal force (N) at 1.0 mm downward displacement in C30, C40, CF30, CF40, HL30, and HL40 groups were 0.56 ± 0.02, 0.49 ± 0.02, 0.65 ± 0.02, 0.49 ± 0.01, 0.68 ± 0.02, and 0.73 ± 0.02, respectively, and the stiffness (N/mm) in subgroups were 0.49 ± 0.01, 0.43 ± 0.01, 0.67 ± 0.01, 0.42 ± 0.01, 0.61 ± 0.01, and 0.58 ± 0.02, respectively. SG-HCS subgroups exhibited greater maximal force and stiffness than conventional cannulated screws. Screws of 30 mm in length demonstrated better stability than all 40 mm-length screws in each subgroup. In C30 fixation, the stiffness and maximum force endured increased by 1.16 and 1.12 times, respectively, compared with the C40 fixation method. There were no significant differences between CF30 and SG-HCS groups. Only the F.E.R.I technique combined with the 4.5 mm cannulated screw of 30 mm in length increased the biomechanical stability for Jones fractures.Discussion: These biomechanical findings help clinicians decide on better screw fixation options for greater stability in Jones fractures, especially when large-diameter screws are limited in use. However, this biomechanical testing of intramedullary screw fixation on Jones fracture model lacks clinical validation and no comparisons to extramedullary plate fixations. Moving forward, additional clinical and biomechanical research is necessary to validate our findings.

Publisher

Frontiers Media SA

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3