Development of a Fluorescent Microfluidic Device Based on Antibody Microarray Read-Out for Therapeutic Drug Monitoring of Acenocoumarol

Author:

Salvador J.-Pablo,Brettschneider Thomas,Dorrer Christian,Marco M.-Pilar

Abstract

The development of a proof-of-concept point-of-care (PoC) device for the determination of oral anticoagulants determination is presented. Acenocoumarol (ACL) is prescribed to prevent certain cardiovascular diseases related to the prevention of deep vein thrombosis, pulmonary embolism, myocardial infarction, and stroke. Oral anticoagualant treatment (OAT) represents a population of 2% under treatment which has expenditures about $ 144 million in 2011. The main drawback for OAT is the associated narrow therapeutic window and the unpredictable dose-response relationship, which is one of the main causes for visiting the emergency room at the hospitals. In a previous work, family antibodies were produced for the simultaneous detection of ACL and warfarin (W) depending on the area of application. It was developed in different formats, indirect and direct, either with similar detectabilities and both assays quantifying the oral anticoagulants with high accuracy and reproducibility. We present the implementation of the already developed immunochemical method to a point-of-care (PoC) device to assist on the patient compliance assessment programs. In order to achieve this goal, a first development was performed implementing ACL ELISA assay into a microarray format with fluorescent read-out. The assay was successfully implemented achieving a LOD of 1.23 nM of ACL directly measured in human plasma. Then, a fully integrated microfluidic system is developed which incorporates the specific immunoreagents for the detection of ACL. The immunoreagents were attached onto the glass slide in a microarray format. The system is automatic, rapid, sensitive, and disposable that could help clinicians monitor patients under OAT. According to the fluorescent label of the ACL binding, the chip can be easily read with a scanner. The microfluidic system performed good according to the robust and reproducible signals, and subsequently yielded an accurate result.

Publisher

Frontiers Media SA

Subject

Biomedical Engineering,Histology,Bioengineering,Biotechnology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3