Efficacy comparison of Kirschner-wire tension band and anchor loop plate in treatment of olecranon fracture

Author:

Du Bing,Su Yu,Ma Teng,Ji Shuai,Lu Yao,Zhang Kun,Li Zhong,Li Ming

Abstract

Objective: This study aimed to introduce a new surgical method for the fixation of olecranon fractures, and to compare the biomechanical stability and clinical efficacy of Kirschner wire tension band and anchor loop plate (ALP) in the treatment of olecranon fractures.Methods: A finite element model was established to analyze the mechanical properties of Kirschner wire tension and anchor loop plate fixation for olecranon fracture. The clinical data of 53 patients with olecranon fractures admitted to our hospital from March 2016 to October 2021 were retrospectively analyzed. Among them, 22 cases were fixed with an anchor loop plate (ALP group), and 31 patients were fixed with the Kirschner wire tension band technique. By reviewing the medical records and follow-up results, the final elbow mobility, secondary surgery, postoperative complications and elbow function recovery Mayo score and DASH score were compared between the two groups.Results: The biomechanical analysis of the finite element model showed that under the load of 120 N, the maximum displacement of the Kirschner wire group was 1.09 times that of the ALP group, the maximum stress of the Kirschner wire group was 1.33 times that of the ALP group, and the maximum stress of the olecranon proximal bone of the Kirschner wire group was 2.17 times that of the ALP group. Under the load of 200 N, the maximum displacement of the Kirschner wire group was 1.19 times that of the ALP group. The overall maximum stress of the Kirschner wire group was 1.59 times that of the ALP group, and the maximum stress of the proximal olecranon bone of the Kirschner wire group was 1.99 times that of the ALP group. The average follow-up time of the Kirschner wire and anchor loop plate groups was similar (p > 0.05). The average age of the two groups was identical (p > 0.05). The final elbow mobility in the anchor loop plate group was significantly greater than in the Kirschner wire group (p < 0.05). The Mayo score of the anchor loop plate group was substantially higher than that of the Kirschner wire group at 3 and 12 months after operation (p < 0.05), and the DASH score was significantly lower than that of the Kirschner wire group (p < 0.05). Postoperative complications in the two groups: 1 case (4.5%) in the anchor loop plate group had difficulties with internal fixation stimulation, and no infection occurred; in the Kirschner wire group, 5 cases (16.1%) had complications of internal fixation stimulation, and 1 patient (3.2%) had an infection.Conclusion: The model of olecranon fracture fixed by anchor loop plate and Kirschner wire tension technique was tested under 120 and 200 N tension, and no damage was found, indicating that the newly designed anchor loop plate was safe in mechanical structure. The biomechanical stability of the anchor plate technique is more stable, so it is not easy to have postoperative complications such as fracture block cutting and internal fixation failure. And the secondary operation rate and elbow function have better results. This technique is an effective method for the treatment of olecranon fractures.

Publisher

Frontiers Media SA

Subject

Biomedical Engineering,Histology,Bioengineering,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3