Change in the corneal material mechanical property for small incision lenticule extraction surgery

Author:

Gao Wenjing,Zhao Xinheng,Wang Yan

Abstract

Purpose: To assess the distribution characteristics and related factors of stress-strain index (SSI) values and discuss changes in biomechanical parameters, including SSI, after small incision lenticule extraction (SMILE) surgery.Methods: This study included 253 patients who underwent SMILE (253 eyes). SSI and other biomechanical parameters were measured using corneal visualization Scheimpflug technology before and 3 months after surgery. The data collected included SSI, central corneal thickness (CCT), and eight other dynamic corneal response parameters. The Kolmogorov–Smirnov test, Pearson and partial correlation analyses, and paired-sample t-tests were used for statistical analyses.Results: Both pre-op SSI and ΔSSI follow a normal distribution, while post-op SSI does not follow a normal distribution. The decline in SSI after SMILE surgery was not statistically significant, and the data dispersion of SSI after SMILE surgery was close to that before surgery (p > 0.05). No statistical correlation was noted between SSI values and age and pre-op CCT (all p > 0.05). However, both pre- and post-op SSI values decreased with increasing degree of myopia (all p < 0.05), and weakly correlated with preoperative intraocular pressure and biomechanically corrected intraocular pressure (all p < 0.05). Other biomechanical parameters changed significantly after surgery (all p < 0.001). After SMILE, the magnitude of the deformation at the highest concave, deformation ratio, and integral radius increased significantly (all p < 0.001), while the Ambrosio relational thickness horizontal, stiffness parameter A1, and Corvis biomechanical index decreased significantly (p < 0.001).Conclusion: SSI, which reflects essential corneal material attributes, differs from other corneal biomechanical parameters and remains stable before and after SMILE surgery, and can be used as an indicator to evaluate changes in corneal material properties after SMILE surgery.

Funder

National Natural Science Foundation of China

Publisher

Frontiers Media SA

Subject

Biomedical Engineering,Histology,Bioengineering,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3