Effect of expanded polytetrafluoroethylene thickness on paclitaxel release and edge stenosis in stent graft

Author:

Zhu Qing,Ye Ping,Niu Haifeng,Chang Zhaohua

Abstract

Stent grafts have been widely used to treat lower extremity arterial stenosis or occlusion. However, there are major issues with edge stenosis and loss of patency over time. Paclitaxel-coated stent grafts have been proven to be effective in preventing edge stenosis, but the insufficient amounts of paclitaxel released may limit the effectiveness of drug-eluting stent grafts. In this study, we examined whether paclitaxel-coated expanded polytetrafluoroethylene (ePTFE) stent graft thickness influences paclitaxel release properties and inhibits edge stenosis. Low-, medium-, and high-thickness paclitaxel-coated stent grafts were prepared by varying the thickness of inner and outer ePTFE layers. Surface morphologies of the stent grafts were analyzed using a scanning electron microscope. The stent grafts were then implanted in the iliac arteries of 20 healthy swine. Twelve pigs were used to assess edge stenosis, and digital subtraction angiography was performed at day 30 (n = 4), 90 (n = 4), and 180 (n = 4). Histological evaluation of the treated arteries was also performed. Eight pigs were used for pharmacokinetic analysis, and the treated arteries were obtained at day 1 (n = 2), 30 (n = 2), 90 (n = 2) and 180 (n = 2). Scanning electron microscopy confirmed that the mean pore size of the stent grafts decreased with increasing thickness. The results of angiographic and histological evaluation demonstrated that low-thickness ePTFE-stent grafts resulted in edge stenosis and apparent intimal hyperplasia at 180 days, whereas for medium-thickness ePTFE-stent grafts, no obvious edge stenosis and intimal hyperplasia was noted in the similar time period. The results of pharmacokinetic evaluation showed that at 180 days, the paclitaxel concentration of treated arteries of the medium group was 36 ± 53 ng/g, while concentrations in the low group was not detectable. Stent grafts with increased ePTFE thickness appear to allow for more delayed release of paclitaxel compared to low-thickness ePTFEs.

Publisher

Frontiers Media SA

Subject

Biomedical Engineering,Histology,Bioengineering,Biotechnology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3