Validation of the German Montreal-Cognitive-Assessment-H for hearing-impaired

Author:

Völter Christiane,Fricke Hannah,Faour Sarah,Lueg Gero,Nasreddine Ziad S.,Götze Lisa,Dawes Piers

Abstract

BackgroundHearing loss and dementia are highly prevalent in older age and often co-occur. Most neurocognitive screening tests are auditory-based, and performance can be affected by hearing loss. To address the need for a cognitive screening test suitable for people with hearing loss, a visual version of the Montreal-Cognitive-Assessment was developed and recently validated in English (MoCA-H), with good sensitivity and specificity for identifying cases of dementia. As the MoCA is known to perform differently across languages, revalidation of the German MoCA-H was necessary. The aim of the present study was to assess the diagnostic accuracy of the German MoCA-H among those with normal cognition, mild cognitive impairment (MCI) and dementia and to determine an appropriate performance cut- off.Materials and methodsA total of 346 participants aged 60–97 years (M = 77.18, SD = 9.56) were included; 160 were cognitively healthy, 79 with MCI and 107 were living with dementia based on the GPCOG and a detailed medical questionnaire as well as a comprehensive examination by a neurologist in case of cognitive impairment. Performance cut-offs for normal cognition, MCI and dementia were estimated for the MoCA-H score and z-scores using the English MoCA-H cut-off, the balanced cut-off and the Youden’s Index.ResultsA mean score of 25.49 (SD = 3.01) points in the German MoCA-H was achieved in cognitively healthy participants, 20.08 (SD = 2.29) in the MCI and 15.80 (SD = 3.85) in the dementia group. The optimum cut-off for the detection of dementia was ≤21 points with a sensitivity of 96.3% and a specificity of 90%. In the MCI group, a cut-off range between 22 and 24 points is proposed to increase diagnostic accuracy to a sensitivity and specificity of 97.5 and 90%, respectively.ConclusionThe German MoCA-H seems to be a sensitive screening test for MCI and dementia and should replace commonly used auditory-based cognitive screening tests in older adults. The choice of a cut-off range might help to better reflect the difficulty in clinical reality in detecting MCI. However, screening test batteries cannot replace a comprehensive cognitive evaluation.

Publisher

Frontiers Media SA

Subject

Cognitive Neuroscience,Aging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3