Single-voxel delay map from long-axial field-of-view PET scans

Author:

Nielsen Frederik Bay,Lindberg Ulrich,Bordallo Heloisa N.,Johnbeck Camilla Bardram,Law Ian,Fischer Barbara Malene,Andersen Flemming Littrup,Andersen Thomas Lund

Abstract

ObjectiveWe present an algorithm to estimate the delay between a tissue time-activity curve and a blood input curve at a single-voxel level tested on whole-body data from a long-axial field-of-view scanner with tracers of different noise characteristics.MethodsWhole-body scans of 15 patients divided equally among three tracers, namely [15O]H2O, [18F]FDG and [64Cu]Cu-DOTATATE, which were used in development and testing of the algorithm. Delay times were estimated by fitting the cumulatively summed input function and tissue time-activity curve with special considerations for noise. To evaluate the performance of the algorithm, it was compared against two other algorithms also commonly applied in delay estimation: name cross-correlation and a one-tissue compartment model with incorporated delay. All algorithms were tested on both synthetic time-activity curves produced with the one-tissue compartment model with increasing levels of noise and delays between the tissue activity curve and the blood input curve. Whole-body delay maps were also calculated for each of the three tracers with data acquired on a long-axial field-of-view scanner with high time resolution.ResultsOur proposed model performs better for low signal-to-noise ratio time-activity curves compared to both cross-correlation and the one-tissue compartment models for non-[15O]H2O tracers. Testing on synthetically produced time-activity curves showed only a small and even residual delay, while the one-tissue compartment model with included delay showed varying residual delays.ConclusionThe algorithm is robust to noise and proves applicable on a range of tracers as tested on [15O]H2O, [18F]FDG and [64Cu]Cu-DOTATATE, and hence is a viable option offering the ability for delay correction across various organs and tracers in use with kinetic modeling.

Publisher

Frontiers Media SA

Reference23 articles.

1. Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography;Iida;AHA Journals: Circulation,1988

2. Parametric imaging of myocardial blood flow with 15O-water and PET using the basis function method;Watabe;J Nucl Med,2005

3. Brain perfusion estimation by Tikhonov model-free deconvolution in a long axial field of view PET/CT scanner exploring five different PET tracers;Larsson;Eur J Nucl Med Mol Imaging,2023

4. Quantitative assessment of tumor metabolism using FDG-PET imaging;Weber;Nucl Med Biol,2000

5. Deriving physiological information from PET images: from SUV to compartmental modelling;Bertoldo;Clin Transl Imaging,2014