Author:
Marciniak Agnieszka,Juniewicz Małgorzata,Ciesielski Bartłomiej,Prawdzik-Dampc Anita,Karczewski Jakub
Abstract
In this article we present results of our follow-up studies of samples of watch glass obtained and examined within a framework of international intercomparison dosimetry project RENEB ILC 2021. We present three methods of dose reconstruction based on EPR measurements of these samples: calibration method (CM), added dose method (ADM) and added dose&heating method (ADHM). The study showed that the three methods of dose reconstruction gave reliable and similar results in 0.5–6.0 Gy dose range, with accuracy better than 10%. The ADHM is the only one applicable in a real scenario, when sample-specific background spectrum is not available; therefore, a positive verification of this method is important for future use of EPR dosimetry in glass in potential radiation accidents.
Subject
Public Health, Environmental and Occupational Health
Reference25 articles.
1. Radiation-induced signals analysed by EPR spectrometry applied to fortuitous dosimetry28796
TrompierF
BassinetC
WieserA
De AngelisC
ViscomiD
FattibeneP
19861734Ann Inst Super Sanita.452009
2. Application of EPR dosimetry in bone for ex vivo measurements of doses in radiotherapy patients;Krefft;Radiat Prot Dosim.,2014
3. Verification of radiotherapy doses by EPR dosimetry in patients' teeth;Kaminska;Radiat Meas.,2016
4. dosimetry with tooth enamel: a review;Fattibene;Appl Radiat Isot.,2010
5. EPR dosimetry in nails—A review;Marciniak;Appl Spectrosc Rev.,2016
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献