Author:
Kittisares Sarin,Ide Tohru,Nabae Hiroyuki,Suzumori Koichi
Abstract
Introduction: Robotic exoskeletons are emerging technologies that have demonstrated their effectiveness in assisting with Activities of Daily Living. However, kinematic disparities between human and robotic joints can result in misalignment between humans and exoskeletons, leading to discomfort and potential user injuries.Methods: In this paper, we present an ergonomic knee exoskeleton based on a dual four-bar linkage mechanism powered by hydraulic artificial muscles for stair ascent assistance. The device comprises two asymmetric four-bar linkage mechanisms on the medial and lateral sides to accommodate the internal rotation of the knee and address the kinematic discrepancies between these sides. A genetic algorithm was employed to optimize the parameters of the four-bar linkage mechanism to minimize misalignment between human and exoskeleton knee joints. The proposed device was evaluated through two experiments. The first experiment measured the reduction in undesired load due to misalignment, while the second experiment evaluated the device’s effectiveness in assisting stair ascent in a healthy subject.Results: The experimental results indicate that the proposed device has a significantly reduced undesired load compared to the traditional revolute joint, decreasing from 14.15 N and 18.32 N to 1.88 N and 1.07 N on the medial and lateral sides, respectively. Moreover, a substantial reduction in muscle activities during stair ascent was observed, with a 55.94% reduction in surface electromyography signal.Discussion: The reduced undesired load of the proposed dual four-bar linkage mechanism highlights the importance of the adopted asymmetrical design for reduced misalignment and increased comfort. Moreover, the proposed device was effective at reducing the effort required during stair ascent.
Funder
Japan Society for the Promotion of Science
Subject
Artificial Intelligence,Computer Science Applications
Reference61 articles.
1. Test method for contact safety assessment of a wearable robot-analysis of load caused by a misalignment of the knee joint;Akiyama,2012
2. Falls in the elderly: spectrum and prevention;Al-Aama;Can. Fam. Physician,2011
3. A study of lower-limb mechanics during stair-climbing;Andriacchi;JBJS,1980
4. Multi-objective optimization of force transmission quality and joint misalignment of a 5-bar knee exoskeleton;Asker,2021
5. Development of a hinge compatible with the kinematics of the knee joint;Bertomeu;Prosthetics Orthot. Int.,2007