Author:
He Baihui,Zhang Fan,Zheng Hui,Sun Xiayu,Chen Junmin,Chen Jianyong,Liu Yupeng,Wang Lu,Wang Wei,Li Shuna,Yang Jun,Duan Maoli
Abstract
Background: Although magnetic resonance imaging (MRI) of the membranous labyrinth and electrocochleography (ECochG) have been used to diagnose endolymphatic hydrops (ELH) in patients with Ménière's disease (MD), the relationship between imaging and ECochG is not well-documented.Objectives: This study evaluates the ELH using 3D-FLAIR MRI and extra-tympanic ECochG (ET-ECochG) and correlates the results from 3D-FLAIR MRI to those from ET-ECochG.Materials and Methods: 3D-FLAIR MRI images of 50 patients were assessed using a 2D volume-referencing grading system (VR scores, relative scores according to the known volumes of the cochlea, vestibule, and semicircular canals). Forty healthy subjects were included and compared to 51 definite MD ears of 50 patients while analyzing the ET-ECochG, which used a self-made bronze foil electrode. The amplitude ratio of the summating potential (SP) to the action potential (AP) (SP/AP) and the area ratio of SP to AP (Asp/Aap) were collected. Relative ELH grade scores were then correlated to ET-ECochG (SP/AP, Asp/Aap).Results: The VR scores showed a better correlation (r = 0.88) with the pure tone average (PTA), disease duration, and vertigo frequency of MD than the Bernaerts scores (grading the cochlea and vestibule separately) (r = 0.22). The SP/AP and Asp/Aap of the unilateral MD patients were statistically comparable to those measured in contralateral ears and the results between the definite MD ears with healthy ears were statistically comparable (p < 0.05). In a ROC analysis Asp/Aap (area under curve, AUC 0.98) significantly (p = 0.01) outperformed SP/AP (AUC 0.91). The total score of ELH, vestibular ELH, and cochlear ELH were also correlated with SP/AP and Asp/Aap. The strongest correlation was found between the Asp/Aap and cochlear ELH (r = 0.60).Conclusion: The 2D volume-referencing grading system was more meaningful than the Bernaerts scores. A correlation was found between ELH revealed by 3D-FLAIR MRI and the SP/AP of ET-ECochG in evaluating definite MD patients. The Asp/Aap appeared a more sensitive and reliable parameter than SP/AP for diagnosing the ELH of the membranous labyrinth.
Subject
Neurology (clinical),Neurology
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献