Autotitrating Bilevel Positive Airway Pressure in Large Vessel Steno-Occlusive Stroke Patients With Suspected Sleep Apnea: A Multicenter Randomized Controlled Study

Author:

Barlinn Kristian,Jakubicek Stanislava,Siepmann Timo,Chernyshev Oleg Y.,Pallesen Lars-Peder,Wienecke Miriam,Hermann Wiebke,Graehlert Xina,Alexandrov Anne W.,Vosko Milan,Puetz Volker,Reichmann Heinz,Bodechtel Ulf,Mikulik Robert,Barlinn Jessica,Alexandrov Andrei V.

Abstract

Background: We hypothesized that autotitrating bilevel positive airway pressure (auto-BPAP) favorably affects short-term clinical outcomes in hyperacute ischemic stroke.Methods: In a multicenter, randomized, controlled trial patients with large vessel steno-occlusive stroke and clinically suspected sleep apnea were allocated to auto-BPAP or standard stroke care alone. Auto-BPAP was initiated within 24 h from stroke onset and performed over 48 h during diurnal and nocturnal sleep. Sleep apnea was assessed using cardiorespiratory polygraphy. Primary endpoint was early neurological improvement on National Institutes of Health Stroke Scale (NIHSS) score at 72 h. Safety and tolerability of BPAP, functional independence [modified Rankin Scale (mRS) 0–2], stroke recurrence, and mortality at 90 days were assessed.Results: Due to low recruitment, the trial was prematurely stopped after 24 patients had been randomized (auto-BPAP, n = 14; control, n = 10): median baseline NIHSS 13 (5.5–18), 88% large vessel occlusion, and 12% large vessel stenosis. Polygraphy confirmed sleep apnea in 64% of auto-BPAP and 88% of control patients (p = 0.34). Adherence to auto-BPAP was achieved by 9 of the 14 (64%) patients. Between auto-BPAP and control patients, no differences were observed in early neurological improvement (median NIHSS change: −2.0, IQR = 7 points vs. −0.5, IQR = 3 points), 90 days functional independence (21 vs. 30%, p = 0.67), stroke recurrence (0 vs. 20%, p = 0.16), and death (14 vs. 20%, p = 1.0). No safety concerns were identified.Conclusions: In this prematurely terminated trial, auto-BPAP was safe but did not show an effect on short-term clinical outcomes in selected ischemic stroke patients. Its tolerability, however, may be limited in hyperacute stroke care and needs to be improved before larger trials are conducted.Clinical Trial Registration:ClinicalTrials.gov, identifier: NCT01812993.

Publisher

Frontiers Media SA

Subject

Clinical Neurology,Neurology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3