First-Pass Reperfusion by Mechanical Thrombectomy in Acute M1 Occlusion: The Size of Retriever Matters

Author:

Serna Candel Carmen,Aguilar Pérez Marta,Bäzner Hansjörg,Henkes Hans,Hellstern Victoria

Abstract

Introduction: Single-pass complete reperfusion using stent retrievers has been shown to improve functional outcome in patients with large vessel occlusion strokes. The aim of this study was to investigate the optimal size of stent retrievers to achieve one-pass complete reperfusion by mechanical thrombectomy.Methods: The study evaluated the results of aspiration-assisted mechanical thrombectomy of acute isolated occlusion of the middle cerebral artery in the M1 segment with a novel 5 × 40-mm stent retriever compared to the usual 4 × 20-mm device. Reperfusion status was quantified using the Thrombolysis In Cerebral Infarction (TICI) scale. We hypothesized that thrombectomy of M1 occlusions with 5 × 40-mm stent retriever yields higher rates of complete first-pass reperfusion (FP) (TICI ≥2c after one pass) and successful or modified FP (mFP) (TICI ≥2b after one pass) than thrombectomy with 4 × 20. We included isolated M1 occlusions treated with pRESET 5 × 40 (phenox) as first-choice device for thrombectomy and compared with M1 occlusions treated with pRESET 4 × 20. We excluded patients with additional occlusions or tandem stenosis or who received an intracranial stent or angioplasty as a part of the endovascular treatment.Results: One hundred thirteen patients were included in the 4 × 20 group and 57 patients in the 5 × 40 group. The 5 × 40 group achieved higher FP compared to 4 × 20 group [61.4% (35 of 57 patients) vs. 40.7% (46 of 113), respectively; adjusted odds ratio (OR) and 95% confidence interval (95% CI) = 2.20 (1.08–4.48), p = 0.030] and a higher mFP [68.4%, 39 of 57 patients vs. 48.7%, 55 of 113; adjusted OR (95% CI) = 2.11 (1.04–4.28), p = 0.037]. Frequency of successful reperfusion (TICI ≥2b) was similar in both groups (100 vs. 97.3%), but frequency of complete reperfusion (TICI ≥2c) was higher in the 5 × 40 group [82.5 vs. 61.9%, adjusted OR (95% CI) = 2.47 (1.01–6.04), p = 0.047]. Number of passes to achieve reperfusion was lower in the 5 × 40 group than in the 4 × 20 group [1.6 ± 1.1 vs. 2 ± 1.4, p = 0.033; adjusted incidence rate ratio (95% CI) = 0.84 (0.69–1.03), p = 0.096]. Modified Rankin scale at 90 days was similar in 5 × 40 and 4 × 20 groups.Conclusions: The size of stent retriever matters in acute M1 occlusions treated with aspiration-assisted mechanical thrombectomy. A longer stent retriever with a larger nominal diameter achieves a higher complete and successful FP and higher successful reperfusion compared to a shorter stent retriever.

Publisher

Frontiers Media SA

Subject

Clinical Neurology,Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3