Indirect Flow Diversion for Off-Centered Bifurcation Aneurysms and Distant Small-Vessel Aneurysms, a Retrospective Proof of Concept Study From Five Neurovascular Centers

Author:

Schob Stefan,Brill Richard,Siebert Eberhard,Sponza Massimo,Schüngel Marie-Sophie,Wohlgemuth Walter Alexander,Götz Nico,Mucha Dirk,Gopinathan Anil,Scheer Maximilian,Prell Julian,Bohner Georg,Gavrilovic Vladimir,Skalej Martin

Abstract

Background: Treatment of cerebral aneurysms using hemodynamic implants such as endosaccular flow disruptors and endoluminal flow diverters has gained significant momentum during recent years. The intended target zone of those devices is the immediate interface between aneurysm and parent vessel. The therapeutic success is based on the reduction of aneurysmal perfusion and the subsequent formation of a neointima along the surface of the implant. However, a subset of aneurysms–off-centered bifurcation aneurysms involving the origin of efferent branches and aneurysms arising from peripheral segments of small cerebral vessels–oftentimes cannot be treated via coiling or implanting a hemodynamic implant at the neck level for technical reasons. In those cases, indirect flow diversion–a flow diverter deployed in the main artery proximal to the parent vessel of the aneurysm–can be a viable treatment strategy, but clinical evidence is lacking in this regard.Materials and Methods: Five neurovascular centers contributed to this retrospective analysis of patients who were treated with indirect flow diversion. Clinical data, aneurysm characteristics, anti-platelet medication, and follow-up results, including procedural and post-procedural complications, were recorded.Results: Seventeen patients (mean age: 60.5 years, range: 35–77 years) with 17 target aneurysms (vertebrobasilar: n = 9) were treated with indirect flow diversion. The average distance between the flow-diverting stent and the aneurysm was 1.65 mm (range: 0.4–2.4 mm). In 15/17 patients (88.2%), perfusion of the aneurysm was reduced immediately after implantation. Follow-ups were available for 12 cases. Delayed opacification (OKM A3: 11.8%), reduction in size (OKM B1-3: 29.4%) and occlusion (D1: 47.1%) were observable at the latest investigation. Clinically relevant procedural complications and adverse events in the early phase and in the late subacute phase were not observed in any case.Conclusion: Our preliminary data suggest that indirect flow diversion is a safe, feasible, and effective approach to off-centered bifurcation aneurysms and distant small-vessel aneurysms. However, validation with larger studies, including long-term outcomes and optimized imaging, is warranted.

Publisher

Frontiers Media SA

Subject

Neurology (clinical),Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3