Tubridge flow diverter for the treatment of small and medium aneurysms

Author:

Xie Dajiang,Yang Heng,Zhao Li,Ye Xin,Yang Shuxu,Gao Chao,Tian Yanlong,Ni Wei,Gu Yuxiang

Abstract

BackgroundTubridge flow diverter is a widely used device aimed at reconstructing parent arteries and occluding complex aneurysms in China. The experience of Tubridge in treating small and medium aneurysms is still limited. In this study, we aimed to evaluate the safety and efficacy of the Tubridge flow diverter for the treatment of the two types of aneurysms.MethodsWe reviewed the clinical records of aneurysms treated with a Tubridge flow diverter between 2018 and 2021 in a national cerebrovascular disease center. Cases were divided into small and medium aneurysms according to aneurysm size. The therapeutic process, occlusion rate, and clinical outcome were compared.ResultsIn total, 57 patients and 77 aneurysms were identified. The patients were divided into two groups: small aneurysms (39 patients, 54 aneurysms) and medium aneurysms (18 patients, 23 aneurysms). There were 19 patients with tandem aneurysms (a total of 39 aneurysms) in the two groups, among which 15 patients (30 aneurysms) were in the small aneurysm group and four patients (nine aneurysms) were in the medium aneurysm group. The results show that the mean maximal diameter/neck in the small and medium aneurysms was 3.68/3.25 and 7.61/6.24 mm, respectively. In total, 57 Tubridge flow diverters were successfully implanted without unfolding failure, and there were six patients with new mild cerebral infarction in the small aneurysm group. The complete occlusion rate on the last angiographic follow-up was achieved in 88.46% of the small aneurysms group and 81.82% of the medium aneurysms group. The complete occlusion rate of patients with tandem aneurysms in the last angiographic follow-up was 86.67% (13/15) of the small aneurysms group and 50% (2/4) of the medium aneurysm group. Intracranial hemorrhage was nonencountered in the two groups.ConclusionOur preliminary experience suggests that the Tubridge flow diverter might be a safe and effective treatment for small and medium aneurysms along the internal carotid artery. Long stents may increase the risk of cerebral infarction. Adequate evidence is required to clarify the definite indications and complications in a multicenter randomized controlled trial with a long-term follow-up.

Funder

National Natural Science Foundation of China

Shanghai Shenkang Hospital Development Center

Publisher

Frontiers Media SA

Subject

Neurology (clinical),Neurology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3