Kinetic pupillary size using Pentacam in myopia

Author:

Li Kaixiu,Li Xiaoqi,Wang Qun,Wang Liqiang,Huang Yifei

Abstract

PurposeTo compare if the kinetic pupillary changes differs between high myopia (HM) and low/moderate myopia by Pentacam.SettingChinese People’s Liberation Army (PLA) General Hospital, Beijing, China.DesignComparative study.MethodsIn this cross-sectional retrospective study, 44 eyes of 44 patients were recruited in the Refractive Surgery Center of Chinese PLA General Hospital. Eyes were divided into two groups according to the refractive error: low/moderate myopia (22 eyes; −2.99 ± 1.09 D) and HM (22 eyes, −12.93 ± 3.44 D). At the beginning of the experiment, we made trials of scanning one false pupil by Pentacam. All patients underwent the Pentacam examination three times. Pupillary diameters (PD) during the scan process and other parameters were measured using the Pentacam. Coefficient variations of PD (CV) during the different scanning periods were analyzed comparatively between the two groups.ResultsPentacam once time output 25 Scheimpflug images, with 13 ones during the period from 1st to 1.5th s and 12 ones during the period from 2.5th to 3rd s after the scanning onset. For the spatial order on all the 25 meridians, 13 Scheimpflug images came out when the Pentacam rotated from 60° to 153°meridians and the remaining 12 Scheimpflug images from 161° to 245° meridians. Among pupillary parameters, no statistical significance existed in PD25, PD13, and PD12 (pupil diameter’s mean from all, former 13 and remaining 12 of 25 Scheimpflug images, respectively) (P > 0.05) between the two groups. However, there were statistically significant differences in CV25 and CV13 (coefficient variation of the pupil diameters from all and former 13 of 25 images, respectively) (P < 0.001), with no statistical significance in CV12 (coefficient variation of the pupil diameters from remaining 12 of 25 images) between both groups.ConclusionTwenty-five Scheimpflug images on Pentacam had the temporal and the spatial orders. CV in eyes with HM was lower than that in eyes with low/moderate myopia in a certain period of the Pentacam scan. Kinetic pupillary size in HM changed more slowly than that in low/moderate myopia during some scanning period analogous to the phasic response of the pupil reflex.

Publisher

Frontiers Media SA

Subject

General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3