Effect of surface electrode recording area on compound muscle action potential scan processing for motor unit number estimation

Author:

Zhang Dan,Lu Zhiyuan,Gong Weijun,Zhou Ping

Abstract

IntroductionMScanFit is a model-based algorithm for motor unit number estimation (MUNE) from compound muscle action potential (CMAP) scan data. It is a clinically applicable tool because of its quick and automatic implementation. Electrodes with different recording areas were employed to record CMAP scan data in existing studies. However, the effect of electrode recording area on MScanFit MUNE and other CMAP scan parameters has not been studied.MethodsCMAP scan was performed on the abductor pollicis brevis muscle of both hands on 14 healthy subjects using three different electrodes with recording areas of 10 mm × 10 mm, 11 mm × 14 mm, and 22 mm × 26 mm, respectively. Motor unit number was estimated using MScanFit for each CMAP scan. Two motor unit number index parameters, i.e., D50 and step index (STEPIX), were also derived from the CMAP scan data.ResultsNo significant difference in D50, STEPIX, and MScanFit MUNE was observed across three different electrode recording areas, although the amplitude of CMAP decreased significantly when a larger electrode was used. Intraclass correlation coefficients of 0.792 and 0.782 were obtained for MScanFit MUNE and STEPIX, respectively.DiscussionCompared with CMAP amplitude, D50, STEPIX, and MScanFit MUNE are less sensitive to variation in electrode recording area. However, the repeatability of MScanFit MUNE could be compromised by the inconsistency in the electrode recording area.

Publisher

Frontiers Media SA

Reference33 articles.

1. Evaluation of motor neuron excitability by CMAP scanning with electric modulated current;Araújo;Neurosci J,2015

2. Influence of the surface EMG electrode on the compound muscle action potential;Barkhaus;Electromyogr. Clin. Neurophysiol.,2006

3. The electrophysiological muscle scan;Blok;Muscle Nerve,2007

4. Estimating motor unit numbers from a CMAP scan: CMAP scan MUNE;Bostock;Muscle Nerve,2016

5. The effect of surface area of active recording electrode to CMAP parameters;Chang;Zhonghua Yi Xue Za Zhi,1993