Author:
Jurek Agnieszka,Krzesiński Paweł,Gielerak Grzegorz,Witek Przemysław,Zieliński Grzegorz,Kazimierczak Anna,Wierzbowski Robert,Banak Małgorzata,Uziębło-Życzkowska Beata
Abstract
BackgroundCushing’s disease is a rare condition associated with a high cardiovascular risk and hypercortisolemia-related hemodynamic dysfunction, the extent of which can be assessed with a noninvasive method, called impedance cardiography. The standard methods for hemodynamic assessment, such as echocardiography or ambulatory blood pressure monitoring may be insufficient to fully evaluate patients with Cushing’s disease; therefore, impedance cardiography is being currently considered a new modality for assessing early hemodynamic dysfunction in this patient population. The use of impedance cardiography for diagnosis and treatment of Cushing’s disease may serve as personalized noninvasive hemodynamic status assessment and provide a better insight into the pathophysiology of Cushing’s disease. The purpose of this study was to assess the hemodynamic profile of Cushing’s disease patients and compare it with that in the control group.Material and MethodsThis observational prospective clinical study aimed to compare 54 patients with Cushing’s disease (mean age 41 years; with 64.8% of this population affected with arterial hypertension) and a matched 54-person control group (mean age 45 years; with 74.1% of this population affected with arterial hypertension). The hemodynamic parameters assessed with impedance cardiography included the stroke index (SI), cardiac index (CI), systemic vascular resistance index (SVRI), velocity index (VI), (ACI), Heather index (HI), and thoracic fluid content (TFC).ResultsThe Cushing’s disease group was characterized by a higher diastolic blood pressure and a younger age than the control group (82.9 vs. 79.1 mmHg, p=0.045; and 41.1 vs. 44.9 years, p=0.035, respectively). Impedance cardiography parameters in the Cushing’s disease group showed: lower values of SI (42.1 vs. 52.8 ml/m2; p ≤ 0.0001), CI (2.99 vs. 3.64 l/min/m2; p ≤ 0,0001), VI (42.9 vs. 52.1 1/1000/s; p=0.001), ACI (68.7 vs. 80.5 1/100/s2; p=0,037), HI (13.1 vs. 15.2 Ohm/s2; p=0.033), and TFC (25.5 vs. 27.7 1/kOhm; p=0.006) and a higher SVRI (2,515 vs. 1,893 dyn*s*cm-5*m2; p ≤ 0.0001) than those in the control group.ConclusionsCushing’s disease is associated with significantly greater vasoconstriction and left ventricular systolic dysfunction. An individual assessment with impedance cardiography may be useful in Cushing’s disease patients in order to identify subclinical cardiovascular complications of chronic hypercortisolemia as potential therapeutic targets.
Funder
Wojskowy Instytut Medyczny
Subject
Endocrinology, Diabetes and Metabolism
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献