Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols

Author:

Pérez José J.,Watson Clifford H.,Blount Benjamin C.,Valentín-Blasini Liza

Abstract

We developed a quantitative method for analyzing nicotine and menthol in e-cigarette, or vaping, products (EVPs). These products may adversely impact health through inhalational exposure to addictive and harmful chemicals. The presence of unknown substances in do-it-yourself e-liquids, counterfeits, or unregulated products may increase exposure to harmful chemicals, as underscored by the 2019 EVP use-associated lung injury (EVALI) outbreak. To minimize these risks, it is important to accurately quantify nicotine and menthol in e-liquids and aerosol emissions to evaluate EVP authenticity, verify product label accuracy, and identify potentially hazardous products. We developed a simple, versatile, high-throughput method using isotope-dilution gas chromatography-mass spectrometry for quantifying nicotine and menthol concentrations in both e-liquid contents and machine-generated aerosol emissions of EVPs. Rigorous validation has demonstrated that the method is specific, precise (CV<2.71%), accurate (percent error ≤7.0%), and robust. Linear calibration ranges from 0.01 to 1.00 mg/ml for both analytes was achieved, corresponding to expected analyte levels in e-liquids and machine-generated EVP aerosols. Limits of detection (LODs) in the final 10-ml sample extract were 0.4 μg/ml for nicotine and 0.2 μg/ml for menthol. The method was used to analyze aerosol emissions of 141 EVPs associated with the 2019 EVALI outbreak; detectable levels of nicotine (2.19–59.5 mg/g of aerosol) and menthol (1.09–10.69 mg/g of aerosol) were observed in 28 and 11%, respectively, of the samples analyzed. Nicotine was not detected in any of the tetrahydrocannabinol (THC), cannabidiol (CBD), or oil-based products, while menthol (2.95 mg/g of aerosol) was only detected in one of these products (THC-labeled). The analytical method can be used to quantify nicotine and menthol concentrations in the e-liquids and aerosols from a range of EVPs, and these findings highlight a difference between e-cigarette and other vaping products.

Publisher

Frontiers Media SA

Subject

General Chemistry

Reference24 articles.

1. Vitamin E Acetate in Bronchoalveolar-Lavage Fluid Associated with EVALI;Blount;N. Engl. J. Med.,2020

2. Multi-rule Quality Control for the Age-Related Eye Disease Study;Caudill;Statist. Med.,2008

3. Outbreak of Lung Injury Associated with the Use of E-Cigarette, or Vaping, Products2019

4. A Comparison of Calculation Procedures for Isotope Dilution Determinations Using Gas Chromatography Mass Spectrometry;Colby;Biol. Mass. Spectrom.,1979

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3