Examining the psychometric properties of the Columbia Speech Quality Instrument in cochlear implant users

Author:

Lalwani Anil K.,Chun Michael B.,Hwa Tiffany P.,Chern Alexander,Tian Likun,Chen Stephanie Y.,Stewart Michael G.,Mancuso Dean,Cellum Ilana P.

Abstract

ObjectiveAlthough speech recognition among cochlear implant (CI) users improved over the past few decades, many still report poor speech quality. Currently, there is no validated tool to measure speech quality. The objective was to examine whether a previously validated speech quality tool is applicable in the CI population using psychometric analysis.DesignCross-sectional psychometric analysis of the Columbia Speech Quality Instrument (CSQI; previously validated in normal-hearing individuals; consists of 2 original and 7 manipulated speech clips designed to accentuate selected speech characteristics) was performed in adult English-speaking CI recipients (N = 36). Subjects rated each clip using a visual analog scale (VAS) on 14 characteristics: cartoonish/not-cartoonish, clear/unclear, like/dislike, breathy/not-breathy, smooth/rough, echo-y/not-echo-y, tinny/bassy, soothing/not-soothing, natural/unnatural, mechanical/not-mechanical, hoarse/smooth, pleasant/unpleasant, male/female, and speech-like/not-speech-like. Main outcome measures included validity, reliability, and factor structure.ResultsContent validity was previously confirmed during instrument design. Construct validity by item-item correlation analysis demonstrated correlation of 12/14 items with ≥1 other retained item (r ≥ 0.35, Spearman). Reliability was confirmed by internal consistency; factor analysis using two subsets selected by Scree plot and factor loading ≥0.4 demonstrated Cronbach alpha coefficients of 0.89 and 0.74 for factors 1 and 2, respectively. Tinny/bassy and male/female were the only characteristics that did not pass construct validity or internal consistency.ConclusionsThe CSQI has strong psychometric properties in the CI population; however, our findings support removal of tinny/bass and male/female characteristics from the final instrument prior to implementation in the CI population. The CSQI can be utilized in cochlear implantees to investigate effects of changes in speech processing strategies and postoperative outcomes with different devices.

Publisher

Frontiers Media SA

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3