Near-infrared reflectance spectroscopy using a portable instrument to measure the nutritive value of oilseed meals as livestock feed

Author:

Walelegne Mulugeta,Meheret Fentahun,Derseh Melkamu B.,Dejene Mesfin,Asmare Yonas T.,Prasad Kodukula V. S. V.,Jones Chris S.,Dixon Robert M.,Duncan Alan J.

Abstract

IntroductionMeasurement of the nutritive value of feedstuffs with near infrared reflectance spectroscopy (NIRS) laboratory benchtop spectrometers is well-established. The aim of this study was to examine the reliability and accuracy of a handheld low-cost Tellspec NIRS spectrometer for measurement of the nutritive value of oilseed meals.MethodsSamples (n=142) comprising byproduct meals from processing linseed, noug seed, cotton seed, groundnut, rapeseed, soybeans, and sunflower seeds were collected from farms, oil factories, wholesalers, and retail shops in central Ethiopia. Samples were scanned ‘as received’ (UGr) and also following drying and grinding (Gr), and were scanned once, twice, and ten times in a 2x3 factorial experimental design. Laboratory analyses of total nitrogen (TN), neutral detergent fiber (NDF), acid detergent fiber (ADF), acid detergent lignin (ADL), and in vitro organic matter digestibility (IVOMD) provided reference measurements. Calibration models were developed using a subset of 2/3 of the spectra and validated using the remaining 1/3 of sample spectra.ResultsThe sample form and the number of scans, and their interactions, all significantly affected the accuracy of the calibration models (P<0.001). The most accurate calibrations were with Gr samples scanned 10 times, where the coefficient of determination of both calibration and validation sets (R2cal and R2val) were ≥ 0.90 for most attributes. The respective standard errors of prediction (SEP) (g/kg DM) for Gr, and ‘as received’, samples respectively that were scanned ten times were: TN (3.2 and 4.7), IVOMD (11.7 and 20.1), NDF (26.9 and 43.8), ADF (25.3 and 44.6), and ADL (6.8 and 10.7). Also, the SEP for each attribute was reduced (P<0.05) by drying and grinding the sample before scanning. The ratios of the standard deviation of the calibration samples to the SEP (RPD) g/kg DM were 2.68, 2.30, 3.17, 3.05, and 4.06 for TN, IVOMD, NDF, ADF, and ADL, respectively, for Gr samples scanned ten times. Nevertheless, the SEP of samples scanned ‘as received’ would often be acceptable for routine analyses in the field and market-place under east African circumstances.ConclusionIn conclusion, NIRS calibrations for a portable handheld Tellspec NIRS spectrometer could be developed to measure important nutritional attributes of oilseed cake samples as feeds.

Funder

United States Agency for International Development

Bill and Melinda Gates Foundation

Publisher

Frontiers Media SA

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3