Systematic Review and Meta-Analysis of Published Studies on Endovascular Repair of Abdominal Aortic Aneurysm With the p-Branch

Author:

Wu Haoliang,Zhang Liwei,Li Mingxing,Wei Shunbo,Zhang Cong,Bai Hualong

Abstract

BackgroundEndovascular treatment of juxtarenal or pararenal abdominal aortic aneurysms is more popular than open surgery, mainly because it reduces perioperative mortality and morbidity. The custom-made fenestrated devices need to be tailored to each patient, so these devices require extra manufacturing and shipping time. The increased wait time may increase the risk of aneurysm rupture in some patients. In some situations, “Off-the-shelf” (OTS) fenestrated grafts can be used. The Cook Zenith p-Branch device (William Cook Australia, Brisbane, Australia) is a relatively common OTS. This study aimed to systematically evaluate all published experiences with p-Branch.MethodsWe searched PubMed, Embase, and Cochrane to find works of literature that reported on the outcomes of patients treated with the p-Branch stent-grafts. Then we conducted an assessment of quality and meta-analysis of the results. The primary endpoints were the application rate of p-Branch stent-graft (type A, B), technical success rate, and early re-intervention rate. We estimated pooled proportions and 95% CIs.ResultsInitial search of the literature included 111 articles, of which 7 studies were included in the end. A total of 260 patients were enrolled in these studies, and 218 patients were eventually treated with p-Branch. The pooled application rate of type A devices was 48% (95% CI, 29–67%), and pooled application rate of type B devices was 30% (95% CI, 16–44%). The pooled technical success rate was 87% (95% CI, 75–98%). The early re-intervention rate was 10% (95% CI, 3–17%). Midterm renal infarct rate (after 30 days) was 3% (95% CI, 0–6%). Midterm re-intervention rate (after 30 days) was 30% (95% CI, 3–57%). Midterm renal failure rate (after 30 days) was 6% (95% CI, 2–10%).ConclusionsThis pooled analysis indicated an acceptable technical success rate after p-Branch stent-graft implantation, with early and midterm re-intervention rate and renal failure rate that cannot be ignored. The p-Branch repair of juxtarenal abdominal aortic aneurysms may be an appropriate and safe option, especially in emergency situations.

Funder

National Natural Science Foundation of China

Publisher

Frontiers Media SA

Subject

Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3