The long-term curative effect analysis of trans-articular plate combined with Kirschner wires in the treatment of fracture-dislocation of the fifth carpometacarpal joint

Author:

Zhou Ying,Wu Ye,Huang Yinjun,Xie Renguo,Gu Song

Abstract

PurposeTo evaluate the long-term curative effect analysis of trans-articular plate combined with Kirschner wires in the treatment of fracture-dislocation of the fifth carpometacarpal joint.MethodsFrom July 2016 to September 2021, 21 patients with fracture-dislocation of the fifth carpometacarpal joint were treated with trans-articular plate combined with Kirschner wires internal fixation. Each patient's gender, age, dominant hand, injured hand, trauma mechanism, the time between injury and surgery, the range of motion of the bilateral wrist in flexion, extension, radial deviation and ulnar deviation, grip strength of each side, the time of return to work, and follow-up time were recorded. The QDASH score and Cooney wrist function score were used to evaluate the postoperative function. The VAS system was used to evaluate postoperative pain.ResultsThe follow-up time was 37.0 ± 19.0 months and the time between injury and surgery was 1.3 ± 0.5 days. In the injured side and the contralateral side, the range of motion of the wrist flexion were 58.3 ± 4.0° and 60.5 ± 3.1°, the range of motion of the wrist radial deviation were 25.7 ± 3.3° and 26.9 ± 2.9°, the range of motion of the wrist ulnar deviation were 28.1 ± 3.7° and 29.5 ± 3.1° respectively with no significant difference. The range of motion of the wrist extension (54.0 ± 3.4°) in the injured side was smaller than that in the contralateral side (56.7 ± 3.7°) with significant difference. The grip strength of the injured side and the contralateral side were 96.1 ± 9.5 LB and 100.7 ± 9.7LB respectively with no significant difference. The QDASH score was 3.8 ± 1.8, Cooney wrist function score was 94.5 ± 4.2, VAS score was 1.0 ± 0.8 and the time of return to work was 5.1 ± 0.9 weeks. In the 21 cases, no postoperative complications such as incision infection, failure of internal fixation, fracture nonunion or fracture malunion occurred.ConclusionThe method of trans-articular plate combined with Kirschner wires is one of the alternative treatments for the fracture-dislocation of the fifth carpometacarpal joint. The long-term follow-up results were satisfactory.

Funder

Nanjing Medical University

Publisher

Frontiers Media SA

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3