Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention

Author:

Bourbotte-Salmon Florian,Ferry Tristan,Cardinale Mickaël,Servien Elvire,Rongieras Frédéric,Fessy Michel-Henry,Bertani Antoine,Laurent Frédéric,Buffe-Lidove Margaux,Batailler Cécile,Lustig Sébastien,

Abstract

Introduction: Management of chronic infection following total knee arthroplasty (TKA) is challenging. Rotating hinged prostheses are often required in this setting due to severe bone loss, ligamentous insufficiency, or a combination of the two. The nature of the mechanical and septic complications occurring in this setting has not been well-described. The aim of this study was to evaluate patient outcomes using a hinge knee prosthesis for prosthetic knee infections and to investigate risk factors for implant removal.Methods: This was a retrospective cohort study that included all patients treated in our tertiary level referral center between January 2009 and December 2016 for prosthetic knee infection with a hinge knee prosthesis. Only patients with a minimum 2-year of follow-up were included. Functional evaluation was performed using international knee society (IKS) “Knee” and “Function” scores. Survival analysis comparing implant removal risks for mechanical and septic causes was performed using Cox univariate analysis and Kaplan-Meier curves. Risk factors for implant removal and septic failure were assessed.Results: Forty-six knees were eligible for inclusion. The majority of patients had satisfactory functional outcomes as determined by mean IKS scores (mean knee score: 70.53, mean function score: 46.53 points, and mean knee flexion: 88.75°). The 2-year implant survival rate was 89% but dropped to 65% at 7 years follow-up. The risk of failure (i.e., implant removal) was higher for septic etiology compared to mechanical causes. Patients with American society of anesthesiologists (ASA) score>1, immunosuppression, or with peripheral arterial diseases had a higher risk for septic failure. Patients with acute infection according to the Tsukayamaclassification had a higher risk of failure. Of the 46 patients included, 19 (41.3%) had atleast one infectious event on the surgical knee and most of these were superinfections (14/19) with new pathogens isolated. Among pathogens responsible for superinfections (i) cefazolin and gentamicin were both active in six of the cases but failed to prevent the superinfection; (ii) cefazolin and/or gentamicin were not active in eight patients, leading to alternative systemic and/or local antimicrobial prophylaxis consideration.Conclusions: Patients with chronic total knee arthroplasty (TKA) infection, requiring revision using rotating hinge implant, had good functional outcomes but experienced a high rate of septic failure, mostly due to bacterial superinfection. These patients may need optimal antimicrobial systemic prophylaxis and innovative approaches to reduce the rate of superinfection.

Publisher

Frontiers Media SA

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3